PubMed Health⌕ Search

PubMed · 11330573

Monitoring of long-term peritoneal membrane function.

Abstract

OBJECTIVE: Peritoneal membrane function influences dialysis prescription and clinical outcome and may change with time on treatment. Increasingly sophisticated tools, ranging from the peritoneal equilibration test (PET) to the standard permeability analysis (SPA) and personal dialysis capacity (PDC) test, are available to the clinician and clinical researcher. These tests allow assessment of a number of aspects of membrane function, including solute transport rates, ultrafiltration capacity, effective reabsorption, transcellular water transport, and permeability to macromolecules. In considering which tests are of greatest value in monitoring long-term membrane function, two criteria were set: those that result in clinically relevant interpatient differences in achieved ultrafiltration or solute clearances, and those that change with time in treatment. STUDY SELECTION: Clinical validation studies of the PET, SPA, and PDC tests. Studies reporting membrane function using these methods in either long-term (5 years) peritoneal dialysis patients or longitudinal observations (> 2 years). DATA EXTRACTION: Directly from published data. Additional, previously unpublished analysis of data from the Stoke PD Study. RESULTS: Solute transport is the most important parameter. In addition to predicting patient and technique survival at baseline, there is strong evidence that it can increase with time on treatment. Whereas patients with initially high solute transport drop out early from treatment, those with low transport remain longer on treatment, although, over 5 years, a proportion develop increasing transport rates. Ultrafiltration capacity, while being a composite measure of membrane function, is a useful guide for the clinician. Using the PET (2.27% glucose), a net ultrafiltration capacity of < 200 mL is associated with a 50% chance of achieving less than 1 L daily ultrafiltration at the expense of 1.8 hypertonic (3.86%) exchanges in anuric patients. Using a SPA (3.86% glucose), a net ultrafiltration capacity of < 400 mL indicates ultrafiltration failure. While there is circumstantial evidence that, with time on peritoneal dialysis, loss of transcellular water transport might contribute to ultrafiltration failure, none of the current tests is able to demonstrate this unequivocally. Of the other membrane parameters, evidence that interpatient differences are clinically relevant (permeability to macromolecules), or that they change significantly with time on treatment (effective reabsorption), is lacking. CONCLUSION: A strong case can be made for the regular assessment by clinicians of solute transport and ultrafiltration capacity, a task made simple to achieve using any of the three tools available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J Davies. Monitoring of long-term peritoneal membrane function.. https://pubmed.ncbi.nlm.nih.gov/11330573/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Adsorption, absorption, and biological degradation of ammonia in different biofilter organic media.

A tailor-made apparatus called ammoniometer, which is a batch mode respirometer applied to the study of ammonia biodegradation in biofilter media, has been used to evaluate adsorption, absorption, and biodegradation in five different organic materials (compost, coconut fibre, bark, pruning wastes, and peat) obtained from full-scale biofilters in operation in several waste treatment plants. The results showed that absorption could be represented by a Henry's law linear equation, with values of the Henry coefficient significantly higher (from 1,866 to 15,320) than that of pure water (1,498). Adsorption data were successfully fitted to Langmuir and Freundlich isotherms and maximum adsorption capacity varies from 1.06 to 1.81 mg NH(3)/g dry media. Ammonia biodegradation rates for each organic material were also calculated. Biodegradation rates varied from 0.67 to 7.82 mg NH(3)/kg media/d depending on the material tested. The data obtained showed important differences in the behaviour of the biofilter organic media, which has important implications in the design and modelling of these systems.

Absorption↗

The use of an oil absorber as a strategy to overcome starvation periods in degrading 1,2-dichloroethane in waste gas.

This work investigates the use of an oil absorber as an operational strategy in vapor phase bioreactors exposed to starvation periods, during the treatment of inhibitory pollutants. After being exposed to 1,2-dichloroethane (DCE) starvation periods, the response and stability of a combined oil-absorber-bioscrubber (OAB) system was compared to that of a bioscrubber only (BO) system. In the BO system, after a 5.2 days starvation period, the DCE removal efficiency was reduced to 12%, and 6 days were needed to recover the initial removal efficiency when the DCE feed resumed. The total organic discharged (TOD(DCE)) was 16,500 g(DCE) m(bioscrubber) (-3) after the DCE starvation. Biomass analysis performed using fluorescence in situ hybridisation (FISH) showed that the microbial activity was significantly reduced during the starvation period and that 5 days were needed to recover the initial activity, after the re-introduction of DCE. In contrast, the performance of the OAB system was stable during 5.2 days of DCE starvation. The DCE removal efficiency was not affected when the DCE feed resumed and the TOD(DCE) was significantly reduced to 2,850 g(DCE) m(bioscrubber) (-3). During starvation, the activity of the microbial culture in the OAB system showed a substantially lower decrease than in the BO system and recovered almost immediately the initial activity after the re-introduction of DCE. Additionally, a mathematical model describing the performance of the OAB system was developed. The results of this study show that the OAB system can effectively sustain the biological treatment of waste gas during starvation periods of inhibitory pollutants.

Absorption↗

Pterin pigment granules are responsible for both broadband light scattering and wavelength selective absorption in the wing scales of pierid butterflies.

A small but growing literature indicates that many animal colours are produced by combinations of structural and pigmentary mechanisms. We investigated one such complex colour phenotype: the highly chromatic wing colours of pierid butterflies including oranges, yellows and patterns which appear white to the human eye, but strongly absorb the ultraviolet (UV) wavelengths visible to butterflies. Pierids produce these bright colours using wing scales that contain collections of minute granules. However, to date, no work has directly characterized the molecular composition or optical properties of these granules. We present results that indicate these granules contain pterin pigments. We also find that pterin granules increase light reflection from single wing scales, such that wing scales containing denser granule arrays reflect more light than those with less dense granule collections. As male wing scales contain more pterin granules than those of females, the sexual dichromatism found in many pierid species can be explained by differences in wing scale pterin deposition. Additionally, the colour pattern elements produced by these pterins are known to be important during mating interactions in a number of pierid species. Therefore, we discuss the potential relevance of our results within the framework of sexual selection and colour signal evolution.

Absorption↗