Abstract

Pulsatile release implants were developed that release substances up to 58 days post implantation. With a cylindrical size of 2 mm diameter and 1.8 mm height the matrices can carry as much as 1 mg of drug and allow even for intracranial implantation into a rodent model. The matrices are made of materials that have been used for parenteral applications in humans before such as surface eroding polyanhydrides and bulk eroding poly(D,L-lactic acid) or poly(D,L-lactic acid-co-glycolic acid). The onset of drug release is controlled by the degradation of bulk eroding polymers which are known to exhibit a certain stability over a defined period of time and which start eroding after they reach a critical degree of degradation. The time of drug release onset was found to depend on the molecular weight and the chemical state of the carboxylic acid end of the polymer chain. For testing the onset of release in vivo a nude mouse model was developed where the release of Evan's blue could be observed visually after subcutaneous application. By combining individual matrices with different release onset, a therapeutic system can be composed that releases drugs after implantation at predetermined time points in a preprogrammed way. Potential applications for such matrices is vaccination and local tumor therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Vogelhuber, P Rotunno, E Magni, A Gazzaniga, T Spruss, G Bernhardt, A Buschauer, A Göpferich. 2001-05-18. Programmable biodegradable implants.. https://doi.org/10.1016/s0168-3659(01)00282-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New segmented copolymers containing poly(epsilon-caprolactone) and etheramide segments for the controlled release of bioactive compounds.

Segmented poly(ether-ester-amide)s (PEEAs) derived from poly(epsilon-caprolactone) oligomers, sebacoyl chloride, hydrophilic diamide-diamines based on short sequences of ethylenoxy groups and containing amino acids, were used to produce matrix systems intended for the delivery of metronidazole in the periodontal pocket. PEEAs are soluble in chloroform and insoluble in water and show M(n) values in the range 8.5-18.6 kDa. The melting temperatures (53-59 degrees C) are close to that of poly(epsilon-caprolactone) (PCL) with a similar M(n). The water absorption of PEEAs is improved if compared with that of pure PCL and depends on both the length of oxyethylene sequences and the amino acid number, as well as on copolymer composition. Loaded-films containing 20% (w/w) of metronidazole were prepared by compression-molding. The release rate was diffusive in the first stage, whereas also other mechanisms, probably polymer degradation, contributed to the slower second phase. The rate of medium penetration within the film depended on PEEA hydrophilicity and crystallinity and was the main determinant governing the drug release rate. The opportunity to control effectively drug release rates by modulating the composition, and in turn the properties, of PEEAs is an attracting feature for their use in a number of drug delivery systems.

Absorbable Implants↗

Mechanical stretch regimen enhances the formation of bioengineered autologous cardiac muscle grafts.

BACKGROUND: Surgical repair of congenital and acquired cardiac defects may be enhanced by the use of autologous bioengineered muscle grafts. These tissue-engineered constructs are not optimal in their formation and function. We hypothesized that a mechanical stretch regimen applied to human heart cells that were seeded on a three-dimensional gelatin scaffold (Gelfoam) would improve tissue formation and enhance graft strength. METHODS AND RESULTS: Heart cells from children undergoing repair of Tetralogy of Fallot were isolated and cultured. Heart cells were seeded on gelatin-matrix scaffolds (Gelfoam) and subjected to cyclical mechanical stress (n=7) using the Bio-Stretch Apparatus (80 cycles/minute for 14 days). Control scaffolds (n=7) were maintained under identical conditions but without cyclical stretch. Cell counting, histology, and computerized image analysis determined cell proliferation and their spatial distribution within the tissue-engineered grafts. Collagen matrix formation and organization was determined with polarized light and laser confocal microscopy. Uniaxial tensile testing assessed tissue-engineered graft function. Human heart cells proliferated within the gelatin scaffold. Remarkably, grafts that were subjected to cyclical stretch demonstrated increased cell proliferation and a marked improvement of cell distribution. Collagen matrix formation and organization was enhanced by mechanical stretch. Both maximal tensile strength and resistance to stretch were improved by cyclical mechanical stretch. CONCLUSION: The cyclical mechanical stretch regimen enhanced the formation of a three-dimensional tissue-engineered cardiac graft by improving the proliferation and distribution of seeded human heart cells and by stimulating organized matrix formation resulting in an order of magnitude increase in the mechanical strength of the graft.

Absorbable Implants↗

Tissue engineering of functional trileaflet heart valves from human marrow stromal cells.

BACKGROUND: We previously demonstrated the successful tissue engineering and implantation of functioning autologous heart valves based on vascular-derived cells. Human marrow stromal cells (MSC) exhibit the potential to differentiate into multiple cell-lineages and can be easily obtained clinically. The feasibility of creating tissue engineered heart valves (TEHV) from MSC as an alternative cell source, and the impact of a biomimetic in vitro environment on tissue differentiation was investigated. METHODS AND RESULTS: Human MSC were isolated, expanded in culture, and characterized by flow-cytometry and immunohistochemistry. Trileaflet heart valves fabricated from rapidly bioabsorbable polymers were seeded with MSC and grown in vitro in a pulsatile-flow-bioreactor. Morphological characterization included histology and electron microscopy (EM). Extracellular matrix (ECM)-formation was analyzed by immunohistochemistry, ECM protein content (collagen, glycosaminoglycan) and cell proliferation (DNA) were biochemically quantified. Biomechanical evaluation was performed using Instron(TM). In all valves synchronous opening and closing was observed in the bioreactor. Flow-cytometry of MSC pre-seeding was positive for ASMA, vimentin, negative for CD 31, LDL, CD 14. Histology of the TEHV-leaflets demonstrated viable tissue and ECM formation. EM demonstrated cell elements typical of viable, secretionally active myofibroblasts (actin/myosin filaments, collagen fibrils, elastin) and confluent, homogenous tissue surfaces. Collagen types I, III, ASMA, and vimentin were detected in the TEHV-leaflets. Mechanical properties of the TEHV-leaflets were comparable to native tissue. CONCLUSION: Generation of functional TEHV from human MSC was feasible utilizing a biomimetic in vitro environment. The neo-tissue showed morphological features and mechanical properties of human native-heart-valve tissue. The human MSC demonstrated characteristics of myofibroblast differentiation.

Absorbable Implants↗