PubMed Health⌕ Search

PubMed · 11381569

Evaluating pharmacokinetic/pharmacodynamic models using the posterior predictive check.

Abstract

The posterior predictive check (PPC) is a model evaluation tool. It assigns a value (pPPC) to the probability that the value of a given statistic computed from data arising under an analysis model is as or more extreme than the value computed from the real data themselves. If this probability is too small, the analysis model is regarded as invalid for the given statistic. Properties of the PPC for pharmacokinetic (PK) and pharmacodynamic (PD) model evaluation are examined herein for a particularly simple simulation setting: extensive sampling of a single individual's data arising from simple PK/PD and error models. To test the performance characteristics of the PPC, repeatedly, "real" data are simulated and for a variety of statistics, the PPC is applied to an analysis model, which may (null hypothesis) or may not (alternative hypothesis) be identical to the simulation model. Five models are used here: (PK1) mono-exponential with proportional error, (PK2) biexponential with proportional error, (PK2 epsilon) biexponential with additive error, (PD1) Emax model with additive error under the logit transform, and (PD2) sigmoid Emax model with additive error under the logit transform. Six simulation/analysis settings are studied. The first three, (PK1/PK1), (PK2/PK2), and (PD1/PD1) evaluate whether the PPC has appropriate type-I error level, whereas the second three (PK2/PK1), (PK2 epsilon/PK2), and (PD2/PD1) evaluate whether the PPC has adequate power. For a set of 100 data sets simulated/analyzed under each model pair according to a stipulated extensive sampling design, the pPPC is computed for a number of statistics in three different ways (each way uses a different approximation to the posterior distribution on the model parameters). We find that in general; (i) The PPC is conservative under the null in the sense that for many statistics, prob(pPPC < or = alpha) < alpha for small alpha. With respect to such statistics, this means that useful models will rarely be regarded incorrectly as invalid. A high correlation of a statistic with the parameter estimates obtained from the same data used to compute the statistic (a measure of statistical "sufficiency") tends to identify the most conservative statistics. (ii) Power is not very great, at least for the alternative models we tested, and it is especially poor with "statistics" that are in part a function of parameters as well as data. Although there is a tendency for nonsufficient statistics (as we have measured this) to have greater power, this is by no means an infallible diagnostic. (iii) No clear advantage for one or another method of approximating the posterior distribution on model parameters is found.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Yano, S L Beal, L B Sheiner. 2001. Evaluating pharmacokinetic/pharmacodynamic models using the posterior predictive check.. https://doi.org/10.1023/a%3A1011555016423

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗