Development of a phantom for morphometric X-ray absorptiometry.

Abstract

Morphometric X-ray absorptiometry (MXA) has recently been developed to assess vertebral deformity status using dual energy X-ray absorptiometry (DXA) machines. In contrast to bone densitometry, a vertebral morphometry phantom is not supplied by any machine manufacturer. The aim of this study was to develop a suitable phantom to quantify the accuracy and precision of the vertebral measurement software on three DXA scanners in vitro and to perform a weekly quality control (QC) scan over a 30-month period to evaluate any drift or changes in measurement accuracy over time. The phantom was constructed from Perspex and aluminium to simulate soft tissue and bone, respectively. 13 aluminium rectangles (each 30 mm wide, 25 mm high and 3 mm thick, with edges ("endplates") 6 mm thick) were set into one side of a solid Perspex block to represent the vertebral bodies from the fourth thoracic (T4) to the fourth lumbar (L4). The phantom was scanned on both the Hologic QDR2000plus and the QDR-4500A as well as the Lunar Expert-XL. Three consecutive lateral MXA scans were acquired on the Hologic machines using each of the scan modes available. On the QDR-2000plus, the lateral scan modes available are fast, array and high definition, which are all dual energy modes. These three scan modes are also available on the QDR-4500A, with the addition of a single energy scan mode. Four lateral scans were acquired on the Expert-XL machine using the single scan mode available. Each MXA scan was analysed twice by a trained operator using the standard software supplied by each manufacturer. A QC scan was performed approximately weekly over a 30-month period on only the QDR-4500A machine, and total phantom height was measured from the inferior edge of L4 to the superior edge of T4. Accuracy of "vertebral" height measurement varied between the three DXA machines and between the scan modes available. All underestimated "true" vertebral height by between 0.4% and 8.6%, with the scan modes using finer collimation producing the most accurate results. Repeat analysis precision of vertebral height measurement was best on the QDR-4500A, followed by the Expert-XL, and was poorest on the QDR-2000plus. The QC scans acquired on the QDR-4500A suggested that it was a highly stable machine, little affected by even major repairs. It must be remembered that these in vitro phantom results may not be representative of the true in vivo situation. The MXA phantom appears to be a useful tool for documenting the stability of the mechanical instruments and for checking the long-term consistency of operator precision.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Rea, G M Blake, I Fogelman. 2001. Development of a phantom for morphometric X-ray absorptiometry.. https://doi.org/10.1259/bjr.74.880.740341

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗