Beam hardening correction for computed tomography images using a postreconstruction method and equivalent tissue concept.

Abstract

A postreconstruction method for correcting the beam-hardening artifacts in computed tomography (CT) images is proposed. This method does not require x-ray spectrum measurement. The authors assumed that a pixel in a CT image can be decomposed into equivalent tissue percentages, depending on its CT number. A scout view of the step wedges made of these equivalent tissues was performed to obtain a beam-hardening correction curve for each tissue. Projecting through the CT image from various angles generated simulated projection data and the total thickness of each tissue along the ray. The correction term was estimated using the tissue thickness traveled by the ray, and this term was then added to its corresponding projection data. A second reconstruction using the corrected projection data yielded a beam-hardening corrected image. The preliminary results show that this method reduces beam hardening artifacts by 14% for aluminum and increased the object contrast by 18% near the aluminum-water boundary. The variation in CT numbers at different locations were reduced, and the aluminum CT number also was restored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Chen, K S Chuang, J Wu, H R Lin, M J Li. 2001. Beam hardening correction for computed tomography images using a postreconstruction method and equivalent tissue concept.. https://doi.org/10.1007/s10278-001-0003-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗