PubMed Health⌕ Search

PubMed · 11451647

Automatic multicommmutated flow system for diffusion studies of pharmaceuticals through artificial enteric membrane.

Abstract

An automatic flow procedure with spectrophotometric detection was developed for the study of pharmaceuticals diffusion through an artificial enteric membrane. The manifold comprised two independent flow pathways, gathered by a diffusion unit with two compartments and an enteric lipophilic membrane. The pathways were automatically filled with solutions simulating digestive and plasmatic conditions by means of four solenoid valves. The diffusion of pharmaceuticals from the enteric to the plasmatic compartment was performed in closed loop pathways, and was continuously monitored by a flow cell coupled to the acceptor solution pathway. The volumes of the digestive and plasmatic solutions were 6.0 and 3.6 ml, respectively, which comprised filling unit compartment, pumping tubing and connecting flow lines. Pumping flow rates of donor and acceptor solutions were maintained at 6.0 and 2.5 ml min(-1), respectively. The proposed system was employed in diffusion studies of caffeine and aminophylline, and in the evaluation of the influence of tensioactive agents on the diffusion process. After continuous solutions circulation for 60 min, caffeine concentration in the acceptor stream was ca. 18% of its initial concentration at the digestive compartment. The system could be programmed to perform several replicates, stopping them with different degrees of diffusion without operator assistance. The data generated by the spectrophotometer was read by the microcomputer as a time function, and stored for further mathematical treatment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Sales, B F Reis, M C Montenegro. 2001. Automatic multicommmutated flow system for diffusion studies of pharmaceuticals through artificial enteric membrane.. https://doi.org/10.1016/s0731-7085(01)00352-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Application of micellar electrokinetic chromatography to the quality control of a pharmaceutical preparation containing three bronchodilators.

Theophylline(1,3-dimethylxanthine), dyphylline [7-(2,3-dihydroxypropyl)theophylline] and proxyphylline [7-(beta-hydroxypropyl)theophylline] are three bronchodilators administered jointly in a single pharmaceutical preparation used against asthma. A micellar electrokinetic chromatography (MEKC) method for their resolution using a background electrolyte consisting of 20 mM tetraborate at pH 8.5 and 100 mM sodium dodecyl sulfate is proposed. The method was used to determine the three active principles in a pharmaceutical preparation. The small amount of sample required and the expeditiousness of the procedure allow content uniformity to be determined in individual tablets. The values of the validation parameters for the method (viz. selectivity, linearity, accuracy, precision, limit of detection, limit of quantitation and robustness) are reported. A complete factor design (2(3)x2) including pH, the surfactant concentration and the ionic strength of the background electrolyte as factors was used to estimate robustness. Based on the results, the method is robust enough for quantitation purposes.

Aminophylline↗