PubMed HealthSearch

PubMed · 1146678

Classification of analytical methods.

Abstract

The ideal analytical method is one which has been thoroughly evaluated, collaboratively tested by a number of laboratories, and established by long usage. The development of such procedures is time consuming and expensive. However, a classification scheme which recognizes that methods may be used which have not been fully evaluated or collaboratively tested is useful. A scheme with five classes which has been applied to NIOSH analytical methods is presented. It recognizes that many analytical methods have been developed, that other agencies and organizations have examined the literature and published methods, and that unproved or suggested method may be the only information available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J V Crable, R G Smith. 1975. Classification of analytical methods.. https://doi.org/10.1080/0002889758507223

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Axial evolution of the negative glow in a hollow cathode discharge.

The purpose of these studies was to examine the axial evolution of the negative glow in a hollow cathode discharge. The time-average negative glow profiles along the central axis of a hollow cathode were recorded for 81 pulse widths over the range of 5-25 microseconds in increments of 0.25 microseconds at a constant interpulse delay of 206.4 microseconds. Subsequent numerical processing yielded the instantaneous negative glow profile. The negative glow was viewed through a mesh-covered slot along the length of the hollow cathode. The negative flow profiles were imaged using a vidicon video camera. A PC-based frame grabber digitized the video images and stored them for subsequent processing.

Chemistry Techniques, Analytical

Use of spherical targets to minimize effects of neutron scattering by hydrogen in neutron capture prompt gamma-ray activation analysis.

For hydrogenous targets that are thinner than they are wide, element sensitivities (counts.s-1.mg-1) for determining concentrations of elements by neutron capture prompt gamma-ray activation analysis (PGAA) are enhanced relative to sensitivities obtained from measurements on nonhydrogenous materials. These enhancements are caused mainly by elastic neutron scattering by H, which changes the average neutron fluence rate within the matrix. The magnitude of the effect depends on the macroscopic scattering and absorption cross sections and on the size, shape, and orientation of the target with respect to the neutron beam. Sensitivities increase linearly with H density for thin targets of constant size and shape and also vary with target shape. Theoretical work was shown that element sensitivities for hydrogenous targets in the form of spheres are least affected by neutron scattering. Methods were devised for creating solid spheres and for containing liquids in spherical shapes. Element sensitivities were determined for spheres and disks of several hydrogenous materials. For H, B, Cl, K, Br, and Cd, sensitivities for spheres were found to be less affected by neutron scattering. Exceptions were Sm and Gd sensitivities measured in liquids contained in quartz globes.

Chemistry Techniques, Analytical

Data-processing method to reduce error coefficients for membrane-based analytical systems. 1. Amperometric-based sensor evaluated for quantification of oxygen.

This paper describes the use of a predictive, curve-fitting method to reduce the effects of experimental variables on results obtained with membrane-based devices. Multipoint data from the transient regions of responses are used with suitable models and curve-fitting methods to predict the signal that would be measured for the system at equilibrium. The resulting equilibrium response usually is much less dependent on experimental variables than the transient responses used to predict it. The approach is evaluated for the membrane-based amperometric electrode for oxygen. Current vs time data are used to predict the equilibrium current expected when oxygen concentrations are the same on both sides of the membrane. Predicted equilibrium currents vary linearly with oxygen concentration. Relative to the more common steady-state method, the sensitivity of the predictive method is about 5-fold higher, the measurement time is about 17-fold shorter and the dependencies on membrane thickness and stirring rate are 125- and 8-fold lower, respectively. Pooled standard deviations (n = 40) correspond to uncertainties in oxygen concentration of about 0.009 mmol L-1.

Chemistry Techniques, Analytical