Electrogastrography: physiological basis and clinical application in diabetic gastropathy.

Abstract

Electrogastrography is the recording and measurement of gastric myoelectrical activity from electrodes placed on the surface of the epigastrium. Normal electrogastrograms (EGGs) reflect 3 cycles per min (cpm) gastric myoelectrical activity produced by specialized pacemaker cells, the interstitial cells of Cajal, located in the muscular wall of the gastric corpus and antrum. Gastric dysrhythmias (tachygastrias and bradygastrias) are disturbances of the normal gastric pacesetter potentials and are associated with symptoms of nausea, epigastric fullness, and bloating and with hyperglycemia and delayed gastric emptying. In diabetic gastropathy, the normal 3-cpm electrical rhythm is replaced with bradygastrias, tachygastrias, and mixed or nonspecific dysrhythmias. Diagnosis of gastric dysrhythmias identifies an objective neuromuscular abnormality in diabetic patients with upper gastrointestinal (GI) symptoms. Correction of gastric dysrhythmias decreases upper GI symptoms and may improve gastric emptying all of which may enhance glucose control. The EGG diagnosis of gastric dysrhythmias provides new insights into gastric neuromuscular abnormalities and guides therapies to improve upper GI symptoms in patients with diabetes mellitus.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K L Koch. 2001. Electrogastrography: physiological basis and clinical application in diabetic gastropathy.. https://doi.org/10.1089/152091501750220019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Allergy reactions to insulin: effects of continuous subcutaneous insulin infusion and insulin analogues.

The purification of animal insulin preparations and the use of human recombinant insulin have markedly reduced the incidence but not completely suppressed the occurrence of insulin allergy manifestations. Advances in technologies concerning the mode of delivery of insulin, i.e. continuous subcutaneous insulin infusion (CSII), and the use of insulin analogues, resulting from the alteration in the amino acid sequence of the native insulin molecule, may influence the immunogenicity and antigenicity of native insulin. Instead of increasing allergy reactions, CSII has been reported to represent a successful alternative treatment in diabetic patients presenting local or generalized allergy to insulin or other components (zinc, protamine) of conventional treatment. Most recent reports concern CSII-treated patients using short-acting insulin analogues (essentially insulin lispro), although the precise role of these insulin analogues remains unclear as allergy to them has also been described. Finally, data on antigenicity and immunogenicity of long-acting insulin analogues (glargine, detemir), which may mimic the basal insulin delivery with CSII, remain scarce at present.

Diabetes Mellitus↗

Effects of glucose homeostasis on protein metabolism in patients with advanced chronic kidney disease.

Insulin deficiency is known to be associated with a state of increased muscle protein breakdown; this process is mediated by the ubiquitin-proteasome pathway. Convincing in vitro data are further supported by extensive studies in humans with insulin deprivation and are further substantiated by reversal of muscle protein breakdown with insulin treatment. In patients with end-stage renal disease (ESRD) and diabetes mellitus (DM), muscle protein breakdown is enhanced in both acute and chronic conditions. Recent data also point to the potential protein catabolic effects of insulin resistance combined with insulin deficiency. Because ESRD is associated with a state of insulin resistance, uremic muscle wasting may also be mediated by this pathway.

Diabetes Mellitus↗