PubMed Health⌕ Search

PubMed · 1147389

A routine for safe, effective endotracheal suctioning.

Abstract

A routine for safe, effective endotracheal suctioning is delineated. This routine was established by correlating various periods of augmented tidal ventilation and endotracheal suctioning with continuous arterial oxygen tension measurements. Patients were evaluated at bronchography to determine the effect of head position on suction catheter placement. Inspired oxygen concentrations were measured via an intratracheal catheter during various forms of inhalation therapy and modes of breating. Using these observations, guidelines were established to maximize the benefits and minimize the risks of an endotracheal suction routine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A H Harken. 1975. A routine for safe, effective endotracheal suctioning.. https://pubmed.ncbi.nlm.nih.gov/1147389/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗