PubMed Health⌕ Search

PubMed · 11474358

Image-guided endoscopic spine surgery: Part I. A feasibility study.

Abstract

STUDY DESIGN: A feasibility study was performed to determine the efficacy of computer assistance in endoscopic spine surgery. OBJECTIVES: To assess a new method for computer assistance based on image guidance during thoracoscopic or any endoscopic spine procedure. To evaluate the reproducibility, the sensitivity and the reliability of the technique first in vitro and second in clinical use. SUMMARY OF BACKGROUND DATA: The computer-based, image-guided surgery is now a routine tool used in open spine surgery. Exposure of the anatomy of the vertebra is needed for registration. This methodology is inapplicable in endoscopic approach. Fluoroscopic-based navigation combines the technology of image-guided surgery and C-arm fluoroscopy. The navigation is based on the fluoroscopic images acquired before surgery. This technology is applicable to endoscopic surgery but the navigation is based on fluoroscopic image. The computed tomography images are not exploited. There are no published data on a technique that allows image-guided surgery based on computed tomography and magnetic resonance imaging. METHOD: A laboratory study was performed on a thoracic human spine. One vertebra was marked on the right lateral side of the body with five titanium marks. A percutaneous reference frame was specifically designed to be placed in the pedicle of the same marked vertebrae. The reference frame acted as a 3D localizer and a registration tool. The spine model was scanned including the reference frame. A standard Stealth station treatment guidance platform (Medtronic, Sofamor Danek, Memphis, TN) was used for simulation. The registration was obtained using the reference frame. Twenty navigation procedure trials were done and the error was recorded based on the distance between the anatomical point and the corresponding virtual one. RESULTS: Registration was always possible using the stealth station and a standard spine navigational software (spine 3, Medtronic Sofamor Danek, Memphis, TN). The mean error after registration given by the computer was 0.96 mm. The mean error recorded during the navigation simulation was 1.6 mm. CONCLUSIONS: This technique allows the possibility of computed tomography and magnetic resonance imaging-based, image-guided endoscopic surgery. It is probable that in the near future, as image fusion technology improves, the fluoronavigation based on fluoroscopic images would enable to navigate on multimodal images. Otherwise the technique described in this article is the only reproducible one that allows computed-tomography-based computer assistance during endoscopic procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Assaker, P Cinquin, A Cotten, J P Lejeune. 2001-08-01. Image-guided endoscopic spine surgery: Part I. A feasibility study.. https://doi.org/10.1097/00007632-200108010-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗