PubMed · 11482813

Imaging transmitter release. II. A practical guide to evanescent-wave imaging.

Abstract

Total internal reflection of a laser beam at an interface between two media of different refractive index sets up an evanescent wave field in the medium with lower refractive index. This near field decays over a distance of approximately lambda/5, lambda denoting the wavelength of light, and thus provides a convenient means for the confinement of fluorescence excitation to the near-interface region. Evanescent-wave excitation thereby permits, for example, the observation of individual fluorophores at the surface despite the presence of high concentrations in bulk solution. Although evanescent-wave excitation of fluorescence and the related technique of surface-plasmon resonance have a long record in the study of chemical reactions at surfaces, adsorption kinetics or spectroscopy, their potential for biomedical studies is only gradually emerging. Evanescent-wave microscopy provides high-contrast images of the near-membrane region of cells grown on a glass substrate at unprecedented resolution. At present, no commercial equipment is available for evanescent-wave microscopy. This review aims at readers who want to modify their fluorescence microscope to include an evanescent-wave illumination mode. Starting from the point that every objective exceeding a certain numerical aperture is generating evanescent waves, we demonstrate how the optical path can be modified to suppress the far-field excitation, and how one can switch easily between these types of illumination. The phenomena resulting from interactions of evanescent waves with cells are reviewed. The ways in which systematic variations of the angle of incident light can be used to obtain quantitative information on fluorophore distance, distribution and concentration are also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Oheim. 2001. Imaging transmitter release. II. A practical guide to evanescent-wave imaging.. https://doi.org/10.1007/pl00011350

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗