PubMed Health⌕ Search

PubMed · 11525785

Hypopyon uveitis.

Abstract

Hypopyon uveitis has inflammatory, infective, and neoplastic causes and a high association with systemic disease. Careful questioning of the patient and detailed examination of the eye for other signs is necessary to guide the differential diagnosis and relevant investigations. Because the underlying causes require very different types of investigation and, if missed, can have serious sequelae for the patient, a rational approach based on the understanding of the causes of hypopyon uveitis is imperative. In this review, hypopyon uveitis is considered in the context of the associated ocular and systemic diseases that cause it.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Ramsay, S Lightman. Hypopyon uveitis.. https://doi.org/10.1016/s0039-6257(01)00231-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of 2 A-scans.

PURPOSE: To compare 2 A-scan instruments with regard to differences in measured results for the same patient sample. SETTING: St. Erik's Eye Hospital, Stockholm, Sweden. METHODS: In a study to evaluate the lens-haptic plane concept of intraocular lens (IOL) power calculation, 148 patients eligible for cataract surgery were measured with 2 different A-scan instruments (BVI Axis and Sonomed 1500). The axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) results were analyzed for systematic differences and random errors. RESULTS: The Sonomed 1500 measured systematically longer than the BVI Axis for AL (0.41 mm) and ACD (0.28 mm), although the correlation was good (r = 0.99 and r = 0.87, respectively). The LT correlated poorly (r = 0.18) and showed no systematic trend. The relative random errors (standard deviations) in ACD (7.2%) and LT (18.6%) were larger than that of the AL (0.8%). The systematic difference in the AL corresponds to a 1.0 diopter difference in the A-constant. CONCLUSIONS: The large random errors in the ACD and LT reduce their value as predictors of postoperative IOL position in formulas that use them. Systematic differences in AL can be large enough to require separate formula constants for different pieces of equipment. If this is the situation in 1 setting, there is a risk of mistakes. This confusion could be avoided if there were an agreed standard and a universal calibration procedure for instruments intended for AL measurement.

Anterior Chamber↗

Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes.

PURPOSE: To compare anterior chamber depth (ACD) measurements in phakic and pseudophakic eyes using a slit-beam photographic technique (IOLMaster, Carl Zeiss Meditec AG) with those obtained with the laboratory prototype version of partial coherence interferometry (PCI) and with conventional applanation ultrasound in phakic eyes. SETTING: Department of Ophthalmology, Vienna General Hospital, Vienna University, Vienna, Austria. METHODS: Thirty-three ACDs of 28 patients with age-related cataract were measured preoperatively with a slit-beam photographic technique (IOLMaster) and the prototype version of PCI. In 24 eyes, the ACD was also assessed with applanation ultrasound. In addition, 34 ACDs of 18 pseudophakic patients in a different study population were examined postoperatively with the IOLMaster and PCI. RESULTS: The median ACD in the phakic eyes was 3.06 mm (range 1.93 to 3.90 mm) with the IOLMaster, 3.09 mm with PCI (range 1.49 to 4.06 mm), and 2.87 mm (range 2.18 to 3.33 mm) with applanation ultrasound. The precision was 0.005 mm for PCI and 0.015 mm for IOLMaster measurement. The median difference between the IOLMaster and PCI ACD biometry was 0.01 mm +/- 0.14 (SD) (range -0.44 to 0.17 mm) (P =.71). In pseudophakic eyes, the 2 methods showed a median difference of -0.22 mm (range -0.45 to 1.99 mm) (P >.1) and did not correlate (r = 0.21; P >.2). CONCLUSIONS: In phakic eyes, the difference between IOLMaster and PCI measurements was small and not statistically significant. In pseudophakic eyes, the difference was larger and the methods did not correlate.

Anterior Chamber↗