PubMed Health⌕ Search

PubMed · 11529441

Microstructural effects on microbial survival: phase-separating dextran solutions.

Abstract

Evolving microstructure in a model dextran solution is shown to exert a major influence on the survival of Escherichia coli K-12 frag 1 and Salmonella typhimurium LT2. The microstructure results from microscopic phase separation, which develops over several hours resulting in hardening of the solution into a glassy state. The microstructure is characterized by an array of physical methods including image analysis, electron spin resonance and bulk rheology, and it is shown that bacterial survival depends on the formation of microscopic. water-rich domains and not primarily on bulk water activity or hardness.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B P Hills, C Buff, K M Wright, L H Sutcliffe, Y Ridge. 2001-09-01. Microstructural effects on microbial survival: phase-separating dextran solutions.. https://doi.org/10.1016/s0168-1605(01)00490-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modelling inactivation of Staphylococcus aureus and Yersinia enterocolitica by high-pressure homogenisation at different temperatures.

A detailed study of the inactivation of Staphylococcus aureus and Yersinia enterocolitica by high-pressure homogenisation was performed at, respectively, 25 and 35 different combinations of process temperature and process pressure covering a range of 5-50 degrees C and 100-300 MPa. It appeared that in the entire studied pressure-temperature domain, S. aureus was more resistant to high-pressure homogenisation than Y. enterocolitica. Furthermore, the effect of the process pressure on the inactivation of S. aureus was considerably smaller than on the inactivation of Y. enterocolitica. Also, temperature between 5 and 40 degrees C did not affect inactivation of S. aureus by high-pressure homogenisation, while Y. enterocolitica inactivation was affected by temperature over a much wider range. Different mathematical models were compared to describe the inactivation of both bacteria under the experimental conditions applied. Such pressure-temperature inactivation models form the engineering basis for design, evaluation and optimisation of high-pressure homogenisation processes as a new preservation technique.

Colony Count, Microbial↗

Simple and rapid methods for detecting Salmonella enteritidis in raw eggs.

The Centers for Disease Control and Prevention estimates there were 300,000 cases of Salmonella enteritidis (SE) in 1997. Egg products were associated with many of the cases. To address this problem, many producers implemented flock surveillance of the SE situation at their facilities. A rapid and simple method for detecting SE from poultry samples is critical for the effective implementation of such testing strategies. A lateral flow device for the detection of SE utilized in this study was manufactured by Neogen, Lansing, MI. The test panel is a presumptive qualitative test system that detects only members of Group D1 Salmonella species. A series of studies were conducted to optimize the test procedure for raw eggs with different sample preparations. A novel antigen extraction method was developed for use with the test panel kit. The detection limit of the test panel kit was increased approximately tenfold when the extraction method was used. Detection of SE was 100% in raw egg pools inoculated with 10 SE cells per ml of egg and incubated at a 1:10 ratio in buffered peptone water (BPW) or tetrathionate brilliant green broth (TBG) for 24 h at 37 degrees C. The developed lateral flow test kit could provide a simple, rapid, and inexpensive method for egg producers and processors to test specifically for Salmonella group D1 serovars, such as SE, in egg samples.

Colony Count, Microbial↗

The influence of process parameters for the inactivation of Listeria monocytogenes by pulsed electric fields.

The influence of the electric field strength, the treatment time, the total specific energy and the conductivity of the treatment medium on the Listeria monocytogenes inactivation by pulsed electric fields (PEF) has been investigated. L. monocytogenes inactivation increased with the field strength, treatment time and specific energy. A maximum inactivation of 4.77 log(10) cycles was observed after a treatment of 28 kV/cm, 2000 micros and 3490 kJ/kg. The lethal effect of PEF treatments on L. monocytogenes was not influenced by the conductivity of the treatment medium in a range of 2, 3 and 4 mS/cm when the total specific energy was used as a PEF control parameter. A mathematical model based on the Weibull distribution was fitted to the experimental data when the field strength (15-28 kV/cm), treatment time (0-2000 micros) and specific energy (0-3490 kJ/kg) were used as PEF control parameters. A linear relationship was obtained between the log(10) of the scale factor (b) and the electric field strength when the treatment time and the total specific energy were used to control the process. The total specific energy, in addition to the electric field strength and the treatment time, should be reported in order to evaluate the microbial inactivation by PEF.

Colony Count, Microbial↗