A portable dose equivalent meter based on microdosimetry.

Abstract

It is generally accepted that the physical basis of the relative biological effectiveness of different radiations is the difference in the spatial distribution of ionization along the charged particle tracks. Thus it is possible to measure physical quantities which may be related to biological damage, and use them to estimate the radiation protection quantity "dose equivalent". A prototype instrument utilizing a spherical proportional counter and microcomputer to make such measurements has been developed and tested. The detector is filled with gas at low pressure in order to simulate micrometer diameter volumes of tissue. Energy deposition in these small volumes is a stochastic quantity which depends on charged particle stopping power, path length through the site, energy loss straggling, and energy transport by secondary charged particles (delta rays). It has been suggested that this energy deposition distribution be used as a basis for defining radiation quality factor (mean Q). However, to the extent that the energy deposition in the site is proportional to the geometric chord length distribution, energy deposition can also be used to determine the linear energy transfer. The mean quality factor can then be calculated on the basis of the current definition. The prototype instrument uses two amplifiers, with gains of 50 and 1000, processing the pulses from a single detector in order to resolve the wide range of energy deposition events produced by neutron and gamma irradiation. Each amplifier is connected to a specially designed analog to digital converter and a 128 channel multichannel analyzer. A microcomputer controls the system and calculates dose and dose equivalent. Test results for a variety of accelerator produced neutron irradiations show that, from 0.1 to 15 MeV, system accuracy is +/- 0.5 for mean Q and +/- 15% for dose equivalent.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Braby. 1985. A portable dose equivalent meter based on microdosimetry.. https://doi.org/10.1016/0168-583x(85)90137-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The design of a portable cosmic ray three-band neutron detector.

The design of a portable three-band cosmic-ray neutron detector is reported in this article. This instrument has been designed to characterise cosmic ray neutron fields in the upper atmosphere and in cosmic reference field facilities. The design utilises a spherical moderator with a layer of spallation material covering a central (3)He proportional counter. The instrument incorporates twelve lithium-coated diodes, six on the outside of the polyethylene layer and six placed within the structure. The dimensions, materials and arrangement of these in the instrument have been optimised with MCNPX to provide a compromise between the requirements of portability and spectral response.

Cosmic Radiation↗

MIDN: a spacecraft microdosimeter mission.

MIDN (MIcroDosimetry iNstrument) is a payload on the MidSTAR-I spacecraft (Midshipman Space Technology Applications Research) under development at the United States Naval Academy. MIDN is a solid-state system being designed and constructed to measure microdosimetric spectra to determine radiation quality factors for space environments. Radiation is a critical threat to the health of astronauts and to the success of missions in low-Earth orbit and space exploration. The system will consist of three separate sensors, one external to the spacecraft, one internal and one embedded in polyethylene. Design goals are mass <3 kg and power <2 W. The MidSTAR-I mission in 2006 will provide an opportunity to evaluate a preliminary version of this system. Its low power and mass makes it useful for the International Space Station and manned and unmanned interplanetary missions as a real-time system to assess and alert astronauts to enhanced radiation environments.

Cosmic Radiation↗

Past and future application of solid-state detectors in manned spaceflight.

The radiation exposure in space missions can be reduced by careful mission planning and appropriate measures, such as provision of a radiation shelter, but it cannot be eliminated. The reason for that is the high penetration capability of the radiation components owing to their high energies. Radiation is therefore an acknowledged primary concern for manned spaceflight and is a potentially limiting factor for long-term orbital and interplanetary missions. The radiation environment is a complex mixture of charged particles of solar and galactic origin and of the radiation belts, as well as of secondary particles produced in interactions of the galactic cosmic particles with the nuclei of atmosphere of the earth. The complexity even increases by placing a spacecraft into this environment owing to the interaction of the radiation components with the shielding material. Therefore it is a challenge to provide for appropriate measurements in this radiation field, coping with the limited resources on experiment power and mass. Solid-state dosemeters were already chosen for measurements in the first manned flights. Thermoluminescence dosemeters (TLDs) and plastic nuclear track detectors (PNTD) especially found a preferred application because they are light-weighted, need no power supply and they are tissue-equivalent. Most of the data available until 1996 were gathered by using these passive detectors; this especially holds for heavy ion particle spectra. The systems, supplemented by converter foils or fission detectors and bubble detectors, provide information on dose, particle flux-, energy- and linear energy transfer spectra of the ionising radiation and neutron fluxes and doses. From 1989, silicon detectors were used for dose and flux measurements and later on for particle spectrometry. Silicon detectors were demonstrated as a powerful tool for the description of space radiation environment. Optical simulated luminescence (OSL) detectors have now been introduced as a new system in space research. Both, OSL and superheated drop detectors are candidates for personal dosimetry systems. The article will summarise past results, and results of measurements performed recently on the ISS, and conclude with future aspects.