PubMed Health⌕ Search

PubMed · 11549997

[Preventable perinatal mortality].

Abstract

BACKGROUND: Using a critical systematic analysis of perinatal mortality, this study aims to examine, on the basis of current medical and scientific knowledge, whether there are still situations in which feto-neonatal death could be prevented and to define and evaluate the feasibility of realising this goal. METHODS: The concept of preventable feto-neonatal death refers to the number of individuals who could have survived with better pre-, intra and postnatal care. In other words, it indicates the number of deaths that could have been avoided in an almost perfect health organisation and therefore, by reference, the number of inevitable deaths (not preventable). In this field it is important to distinguish between clinically preventable, where there are preventable factors at the time of hospitalisation and during the clinical phase of the disease, and extra-clinically preventable when these factors, if potentially present during the preclinical phase of disease, disappear owing to the gravity of conditions at the time of hospitalisation. Using data from maternal and neonatal clinical records, death certificates and autopsy findings, the authors examined the perinatal mortality rate in Department B of the Gynecological and Obstetrics Clinic of Turin University during the period 1979-1998. The results of these two decades were compared in terms of clinical practice. RESULTS: The perinatal mortality rate fell significantly (p<0.01) during the period 1989-1998: 1.02 vs 1.77%. It is worth underlining that this was mainly the result of a marked reduction (over 50%) in late fetal mortality: 0.43 vs 0.98% (p<0.01). Early neonatal mortality also diminished, although not significantly (0.59 vs 0.79%). In order to evaluate preventable deaths, perinatal mortality was subject to a detailed critical analysis to analyse its chronological evolution: prenatal, intranatal, early neonatal. During the second period examined, the preventable nature of perinatal mortality, although slightly lower, applied to 36.35% of cases. It is important to underline that although clinically preventable deaths were unfortunately still present (approx. 10%), most cases (approx. 90%) referred to extra-clinically preventable deaths. CONCLUSIONS: On the basis of current medical and scientific knowledge, the authors outline the directives for medical and specialist obstetric and social care required in the specific fight against preventable perinatal deaths. Recent progress in basic scientific research, especially in the genetic field, may make a vital contribution to limit and reduce the coefficient of feto-neonatal pathology that is still beyond control.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Colla, E Alba, R Grio. 2001. [Preventable perinatal mortality].. https://pubmed.ncbi.nlm.nih.gov/11549997/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Image-guided and intensity-modulated radiosurgery for patients with spinal metastasis.

BACKGROUND: Radiosurgery can deliver a single, large radiation dose to a localized tumor using a stereotactic approach and hence, requires accurate and precise delivery of radiation to the target. Of the extracranial organ targets, the spine is considered a suitable site for radiosurgery, because there is minimal or no breathing-related organ movement. The authors studied spinal radiosurgery in patients with spinal metastases to determine its accuracy and precision. METHODS: The spinal radiosurgery program was based on an image-guided and intensity-modulated, shaped-beam radiosurgical unit. It is equipped with micromultileaf collimators for beam shaping and radiation intensity modulation and with a noninvasive, frameless positioning device that uses infrared, passive marker technology together with corroborative image fusion of the digitally reconstructed image from computed tomography (CT) simulation and orthogonal X-ray imagery at the treatment position. These images were compared with the port films that were taken at the time of treatment to determine the accuracy of the isocenter position. Clinical feasibility was tested in 10 patients who had spinal metastasis with or without spinal cord compression. The patients were treated with fractionated external beam radiotherapy followed by single-dose radiosurgery as a boost (6-8 grays) to the most involved portion of the spine or to the site of spinal cord compression. RESULTS: The accuracy for the isocenter was within 1.36 mm +/- 0.11 mm, as measured by image fusion of the digitally reconstructed image from CT simulation and the port film. Clinically, the majority of patients had prompt pain relief within 2-4 weeks of treatment. Complete and partial recovery of motor function also was achieved in patients with spinal cord compression. The radiation dose to the spinal cord was minimal. The maximum dose of radiation to the anterior edge of the spinal cord within a transverse section, on average, was 50% of the prescribed dose. There was no acute radiation toxicity detected clinically during the mean follow-up of 6 months. CONCLUSIONS: Image-guided, shaped-beam spinal radiosurgery is accurate and precise. Rapid clinical improvement of pain and neurologic function also may be achieved. The results indicate the potential of spinal radiosurgery in the treatment of patients with spinal metastasis, especially those with solitary sites of spine involvement, to increase the prospects of long-term palliation.

Feasibility Studies↗

Potential and limitations of the automatic detection of fiducial markers using an amorphous silicon flat-panel imager.

Amorphous silicon electronic portal imaging devices (a-Si EPIDs) allow fast acquisition of high resolution portal images (PI). A visualization of organ movement for adaptive image-guided radiotherapy (IGRT) can be reached by implantation and automatic detection of fiducial markers. A method of automatic detection has been developed for fiducial spherical tungsten markers on PIs, acquired with an a-Si flat-panel imager. The detection method consists of a 2D Mexican hat filter (MHF), whose parameters are tuned to the particular marker signal. The high selectivity of this filter allows a reliable and precise detection of tungsten markers down to a diameter of 1.5 mm. The presented method allows fast, automatic and unsupervised detection of markers. Inevitably, the detection is hampered by image background (bone structures, etc) and noise. A detection success rate higher than 95% was reached, analysing PIs of patients with markers fixed on their skin. Furthermore, this approach to automatic marker detection can also be generalized to elliptic MHFs for the detection of cylindrical markers. The accuracy and detection probability of this method may allow accurate and fast online localization of the considered organ.

Feasibility Studies↗

Development of a semi-automatic alignment tool for accelerated localization of the prostate.

PURPOSE: Delivering high dose to prostate with external beam radiation has been shown to improve local tumor control. However, it has to be carefully performed to avoid partial target miss and delivering excessive dose to surrounding normal tissues. One way to achieve safe dose escalation is to precisely localize prostate immediately before daily treatment. Therefore, the radiation can be accurately delivered to the target. Once the prostate position is determined with high confidence, planning target volume (PTV) safety margin might be reduced for further reduction of rectal toxicity. A rapid computed tomography (CT)-based online prostate localization method is presented for this purpose. METHODS AND MATERIALS: Immediately before each treatment session, the patient is immobilized and undergoes a CT scan in the treatment position using a CT scanner situated in the treatment room. At the CT console, posterior, anterior, left, and right extents of the prostate are manually identified on each axial slice. The translational prostate displacements relative to the planned position are estimated by simultaneously fitting these identified extents from this CT scan to a template created from the finely sliced planning CT scan. A total of 106 serial CT scans from 8 prostate cancer patients were performed immediately before treatments and used to retrospectively evaluate the precision of this daily prostate targeting method. The three-dimensional displacement of the prostate with respect to its planned position was estimated. RESULTS: Five axial slices from each treatment CT scan were sufficient to produce a reliable correction when compared with prostate center of gravity (CoG) displacements calculated from physician-drawn contours. The differences (mean +/- SD) between these two correction schemes in the right-left (R/L), posterior-anterior (P/A), and superior-inferior (S/I) directions are 0.0 +/- 0.4 mm, 0.0 +/- 0.7 mm, and -0.4 +/- 1.9 mm, respectively. With daily CT extent-fitting correction, 97% of the scans showed that the entire posterior prostate gland was covered by PTV given a margin of 6 mm at the rectum-prostate interface and 10 mm elsewhere. In comparison, only 74% and 65% could be achieved by the corrections based on daily and weekly bony matching on portal images, respectively. CONCLUSIONS: Results show that daily CT extent fitting provides a precise correction of prostate position in terms of CoG. Identifying prostate extents on five axial CT slices at the CT console is less time-consuming compared with daily contouring of the prostate on many slices. Taking advantage of the prostate curvature in the longitudinal direction, this method also eliminates the necessity of identifying prostate base and apex. Therefore, it is clinically feasible and should provide an accelerated localization of the prostate immediately before daily treatment.

Feasibility Studies↗