PubMed Health⌕ Search

PubMed · 11563654

Screening method for nitroaromatic compounds in water based on solid-phase microextraction and infrared spectroscopy.

Abstract

A new method is described for determining nitroaromatic compounds in water that combines solid-phase microextraction (SPME) and infrared (IR) spectroscopy. In this method, the compounds are extracted from a 250-mL volume of water into a small square (3.2 cm x 3.2 cm x 61.2 microm thick) of silicone polycarbonate copolymer film (MEM-213). Five nitroaromatic compounds, including 2,4,6-trinitrotoluene (TNT), were chosen to evaluate the SPME/IR procedure. Quantitation limits for the five test compounds range from 50 microg/L for TNT to 400 microg/L for nitrobenzene. Precision values, determined at aqueous concentrations of four times the quantitation limit, range from 4 to 7%, and linear dynamic ranges extend to the maximum limit of the IR instrumentation. The potential of this SPME/IR method for determining nitroaromatics in natural water samples was also investigated by extracting "real world" soil samples contaminated with TNT. Results obtained from the SPME/ IR determination of the diluted extracts were in reasonable agreement with those obtained from dichloromethane extraction followed by gas chromatographic analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D C Stahl, D C Tilotta. 2001-09-01. Screening method for nitroaromatic compounds in water based on solid-phase microextraction and infrared spectroscopy.. https://doi.org/10.1021/es010550c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of pesticides by solid phase extraction followed by gas chromatography with nitrogen-phosphorous detection in natural water and comparison with solvent drop microextraction.

The European Union specifies that drinking water can contain pesticide residues at concentrations of up to 0.1 microg/L each and 0.5 microg/L in total, and that 1-3 microg/L of pesticides can be present in surface water, but the general idea is to keep discharges, emissions and losses of priority hazardous substances close to zero for synthetic substances. Therefore, in order to monitor pesticide levels in water, analytical methods with low quantification limits are required. The method proposed here is based on solid phase extraction (SPE) followed by gas chromatography with a nitrogen-phosphorous detector (GC-NPD). During method development, six organophosphate pesticides (azinphos-ethyl, chlorfenvinphos, chlorpyriphos, ethoprophos, fenamiphos and malathion) and two organonitrogen pesticides (alachlor and deltamethrin) were considered as target analytes. Elution conditions that could influence the efficiency of the SPE were studied. The optimized methodology exhibited good linearity, with determination coefficients of better than 0.996. The analytical recovery for the target analytes ranged from 70 to 100%, while the within-day precision was 4.0-11.5%. The data also showed that the nature of the aqueous matrice (ultrapure, surface or drinking water) had no significant effect on the recovery. The quantification limits for the analytes were found to be 0.01-0.13 microg/L (except for deltamethrin, which was 1.0 microg/L). The present methodology is easy, rapid and gives better sensitivity than solvent drop microextraction for the determination of organonitrogen and organophosphate pesticides in drinking water at levels associated with the legislation.

Chromatography, Gas↗

A comparison of a gas chromatographic with electron-capture detection and a gas chromatographic with mass spectrometric detection screening methods for the analysis of famoxadone in grapes and wines.

Famoxadone is a recent oxazolidinedione fungicide widely used in viticulture and in Integrated Pest Management strategies. In this work, after a simple and fast liquid-liquid extraction (LLE), two new gas chromatographic methods were developed to analyze famoxadone residues in grapes and wines, one with electron-capture detection (GC-ECD) and the other with mass spectrometry (GC-MS). Global uncertainties for validation parameters of both methods were compared. Limits of detection (LODs) were 0.06 and 0.02 mg/L, precision was not above 11.7 and 6.8% and recoveries were, on average, 103%+/-12 and 96%+/-12, respectively, for the GC-ECD and GC-MS methods. Similar expanded uncertainties in the range from 0.25 to 1.00 mg/L were below 35%, with increasing values for lower levels of famoxadone. GC-MS method had a lower LOD and a lower uncertainty if compared with the GC-ECD method.

Chromatography, Gas↗

Identification of biologically active triterpenes and sterols present in hexane extracts from Miconia species using high-resolution gas chromatography.

In this work we describe the identification of the biologically active triterpenes and sterols present in the hexane extracts of six species of Miconia using gas chromatography. The main compounds present in these extracts are beta-amyrin, alpha-amyrin, and beta-sitosterol. The technique employed herein is shown to be a valuable and rapid tool for determining biologically active triterpenes and sterols present in non-polar extracts.

Chromatography, Gas↗