PubMed Health⌕ Search

PubMed · 11565721

Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts.

Abstract

BACKGROUND: There is concern that a hypercoagulable status is caused after coronary artery bypass grafting without cardiopulmonary bypass (off-pump coronary artery bypass grafting, or OPCAB) and may potentially endanger the patency of the anastomosis. The aims of this study were: (1) to compare 1-year graft patency after OPCAB with that of conventional coronary artery bypass grafting (CABG) and that of on-pump beating CABG; and (2) to demonstrate any differences in patency of various conduits among the three groups. METHODS: We analyzed the results of 122 consecutive OPCAB cases (group 1) compared with those of 65 consecutive conventional CABG cases (group II) and those of 19 consecutive on-pump beating CABG cases (group III). In group I, coronary angiography (CAG) was performed immediately postoperatively and 1 year after surgery. In groups II and III, CAG was performed 1 year after surgery. Graft patency was graded as grade A (excellent), grade B (fair), or grade O (occluded). RESULTS: The average number of distal anastomoses in groups I, II, and III were 3.1 +/- 1.1, 3.7 +/- 0.9, and 3.6 +/- 0.9, respectively. In group I, postoperative CAG was performed in 92% of patients (112/122) before discharge. The patency rate (grade A + B) was 96.4% (162/168) for arterial grafts, and 85.6% (160/187) for saphenous vein grafts (SVG). One-year follow-up CAG was performed in 74% of patients (90/122). The patency rate was 97.8% (132/135) for arterial grafts and 67.9% (106/156) for SVG. In group II, 1-year follow-up CAG was performed in 65% of patients (42/65). The patency rate (grade A + B) was 93.5% (43/46) for arterial grafts and 88.3% (98/111) for SVG. In group III, 1-year follow-up CAG was performed in 89% of patients (17/19). The patency rate (grade A + B) was 100% (19/19) for arterial grafts and 86.8% (33/38) for SVG. CONCLUSIONS: Our results demonstrate that the patency rate ot SVG after OPCAB was significantly lower than that of arterial grafts in the early postoperative CAG (p < 0.001), and was also significantly lower than those of SVG of group II (p < 0.001) and group III (p < 0.01) in the postoperative 1-year CAG, although there was no significant difference in 1-year patency of arterial grafts among the three groups. Our data suggest that a specific perioperative anticoagulant therapy may be advisable in patients undergoing OPCAB with SVG.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K B Kim, C Lim, C Lee, I H Chae, B H Oh, M M Lee, Y B Park. 2001. Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts.. https://doi.org/10.1016/s0003-4975(01)02946-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Robot-assisted laparoscopic intestinal anastomosis.

INTRODUCTION: Robotic telemanipulation systems have been introduced recently to enhance the surgeon's dexterity and visualization in videoscopic surgery in order to facilitate refined dissection, suturing, and knot tying. The aim of this study was to demonstrate the technical feasibility of performing a safe and efficient robot-assisted handsewn laparoscopic intestinal anastomosis in a pig model. METHODS: Thirty intestinal anastomoses were performed in pigs. Twenty anastomoses were performed laparoscopically with the da Vinci robotic system (robot-assisted group), the remaining 10 anastomoses by laparotomy (control group). OR time, anastomosis time and complications were recorded. Effectiveness of the laparoscopic anastomoses was evaluated by postoperative observation of 10/20 pigs of the robot-assisted group for 14 days and by testing mechanical integrity in all pigs by measuring passage, circumference, number of stitches, and bursting pressure. These parameters and anastomosis time were compared to the anastomoses performed in the control group. RESULTS: In all cases of the robot-assisted group the procedure was completed laparoscopically. The only perioperative complication was an intestinal perforation, caused by an assisting instrument. The median procedure time was 77 min. Anastomosis time was longer in the laparoscopic cases than in the controls (25 vs 10 min; p <0.001). Postoperatively, one pig developed an ileus, based on a herniation of the spiral colon through a trocar-port. For this reason it was terminated on the sixth postoperative day. All anastomoses of the robot-assisted group were mechanically intact and all parameters were comparable to those of the control group. CONCLUSION: Technical feasibility of performing a safe and efficient robot-assisted laparoscopic intestinal anastomosis in a pig model was repeatedly demonstrated in this study, with a reasonable time required for the anastomosis.

Anastomosis, Surgical↗

Influence of vestibulovaginal stenosis, pelvic bladder, and recessed vulva on response to treatment for clinical signs of lower urinary tract disease in dogs: 38 cases (1990-1999).

OBJECTIVE: To determine influence of vestibulovaginal stenosis, pelvic bladder, and recessed vulva on response to treatment for clinical signs of lower urinary tract disease in dogs. DESIGN: Retrospective study. ANIMALS: 38 spayed female dogs. PROCEDURE: Medical records and client follow-up were reviewed for dogs evaluated via excretory urography because of clinical signs of lower urinary tract disease. Clinical signs, results of radiography, and response to surgical or medical treatment were analyzed. RESULTS: Clinical signs included urinary tract infection (n = 24), urinary incontinence (20), vaginitis (11), pollakiuria or stranguria (10), and perivulvar dermatitis (4). Vaginocystourethrographic findings included vestibulovaginal stenosis (n = 28), pelvic bladder (17), and ureteritis or pyelonephritis (4). Ten dogs had a vestibulovaginal ratio of < 0.20 (severe stenosis), 9 dogs had a ratio of 0.20 to 0.25 (moderate stenosis), 9 dogs had a ratio of 0.26 to 0.35 (mild stenosis), and 10 dogs had a ratio of > 0.35 (anatomically normal). Lower urinary tract infection, incontinence, and pelvic bladder were not associated with response to treatment for recessed vulva. Vestibulovaginal stenosis with a ratio < 0.20 was significantly associated negatively with response to treatment. Dogs without severe vestibulovaginal stenosis that received vulvoplasty for a recessed vulva responded well to treatment. CONCLUSIONS AND CLINICAL RELEVANCE: Vestibulovaginal stenosis is likely an important factor in dogs with vestibulovaginal ratio < 0.20. Vaginectomy or resection and anastomosis should be considered in dogs with severe vestibulovaginal stenosis and signs of lower urinary tract disease.

Anastomosis, Surgical↗

Feasibility of pulmonary artery pressure measurements in infants through aorto-pulmonary shunts using a micromanometer pressure wire.

Assessment of pulmonary artery pressure is an essential element in the evaluation of children palliated with surgical aorto-pulmonary shunts prior to definitive surgical repair. We report the ease of use and accuracy of a 0.014 inch micromanometer pressure wire for the measurement of pulmonary artery pressures in children with aorto-pulmonary artery shunts. The study population consisted of 11 infants and children with either a 3.5 mm modified Blalock-Taussig shunt from the subclavian artery to the branch pulmonary artery after stage 1 Norwood repair for hypoplastic left heart syndrome or palliative staged repair for tetralogy of Fallot, or a central shunt for pulmonary atresia or double outlet right ventricle. The unique features of the micromanometer pressure wire allowed rapid access and accurate measurement of pulmonary pressures in all patients studied. We conclude that the micromanometer pressure wire is a unique and accurate alternative device for rapid and safe determinations of pulmonary artery pressures in children with aorto-pulmonary artery shunts.

Anastomosis, Surgical↗