PubMed Health⌕ Search

PubMed · 11567577

Analyzing and correcting spectrometer temperature sensitivity.

Abstract

Stability and reproducibility of the spectrometer are fundamental to the success of many modern NMR experiments. Variation in room temperature is a particularly important source of instability, in part because it can cause coherent artifacts in NMR spectra. Small changes in room temperature lead to corresponding changes in the phases, amplitudes, and frequencies of NMR signals. These can lead in turn to apparently random spectral artifacts such as t(1)-noise in two-dimensional (2D) NMR and to the incomplete cancellation of signals in difference spectra, but also, importantly, to F(1) satellite signals in 2D spectra. These "parallel diagonals" arise from the use of air conditioning, which typically forces room temperature to oscillate within a fixed band. Work to identify, quantify, and suppress sources of temperature sensitivity in a modern 300-MHz spectrometer has led to a greater than 10-fold improvement in the signal-to-artifact ratio.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Bowyer, A G Swanson, G A Morris. 2001. Analyzing and correcting spectrometer temperature sensitivity.. https://doi.org/10.1006/jmre.2001.2404

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of biogenic CO production above vascular cell cultures using a near-room-temperature QC-DFB laser.

We report the first application of pulsed, near-room-temperature quantum cascade laser technology to the continuous detection of biogenic CO production rates above viable cultures of vascular smooth muscle cells. A computer-controlled sequence of measurements over a 9-h period was obtained, resulting in a minimum detectable CO production of 20 ppb in a 1-m optical path above a standard cell-culture flask. Data-processing procedures for real-time monitoring of both biogenic and ambient atmospheric CO concentrations are described.

Air Conditioning↗

Shade trees reduce building energy use and CO2 emissions from power plants.

Urban shade trees offer significant benefits in reducing building air-conditioning demand and improving urban air quality by reducing smog. The savings associated with these benefits vary by climate region and can be up to $200 per tree. The cost of planting trees and maintaining them can vary from $10 to $500 per tree. Tree-planting programs can be designed to have lower costs so that they offer potential savings to communities that plant trees. Our calculations suggest that urban trees play a major role in sequestering CO2 and thereby delay global warming. We estimate that a tree planted in Los Angeles avoids the combustion of 18 kg of carbon annually, even though it sequesters only 4.5-11 kg (as it would if growing in a forest). In this sense, one shade tree in Los Angeles is equivalent to three to five forest trees. In a recent analysis for Baton Rouge, Sacramento, and Salt Lake City, we estimated that planting an average of four shade trees per house (each with a top view cross section of 50 m2) would lead to an annual reduction in carbon emissions from power plants of 16,000, 41,000, and 9000 t, respectively (the per-tree reduction in carbon emissions is about 10-11 kg per year). These reductions only account for the direct reduction in the net cooling- and heating-energy use of buildings. Once the impact of the community cooling is included, these savings are increased by at least 25%.

Air Conditioning↗

The use of heteroduplex analysis of polymerase chain reaction products to support the possible transmission of Legionella pneumophila from a malfunctioning automobile air conditioner.

Air conditioner condensates have not been previously associated with cases of Legionnaires' disease. We report the possible transmission of Legionella pneumophila serogroup 1 from a malfunctioning automobile air conditioning system's leaking water onto the floorboard of a car driven for a long distance by the patient. Heteroduplex analysis of polymerase chain reaction products was used to help establish an epidemiologic link between the water specimen and the patient.

Air Conditioning↗