PubMed Health⌕ Search

PubMed · 11571908

Anesthesia considerations for lung volume reduction surgery.

Abstract

Patient selection is of crucial importance for outcome after lung volume reduction surgery. The anesthesiologist should be involved actively in patient selection, because he or she is in charge of the treatment during the critical perioperative period. Patient history and status and results from chest radiographs, high-resolution CT scans, and catheterization of the right heart should be taken carefully into account in the patient selection process. Promising new results involving functional parameters may predict outcome objectively after lung volume reduction surgery in the future. Careful selection and preoperative preparation of patients also are important to avoid complications and keep the success rate high. The anesthesiologist's understanding of the principles involved is important for the successful conduct of lung volume reduction surgery. It is unclear if lung volume reduction surgery is superior to conventional therapy in the long run because the decline in lung function is progressive after the procedure. A multicenter trial comparing patients undergoing lung volume reduction surgery with patients with emphysema who are treated conventionally hopefully will clarify this important question in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E M Tschernko. 2001. Anesthesia considerations for lung volume reduction surgery.. https://doi.org/10.1016/s0889-8537(05)70249-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evoked prefrontal gamma oscillation by hippocampal train stimulation in anesthetized rats.

We previously reported a difference in short-term synaptic plasticity between the rat posterior dorsal CA1 (pdCA1)-prefrontal cortex (PFC) and ventral CA1 (vCA1)-PFC pathways. Here, to determine the effects of hippocampal train stimulation on the local field potential in the medial PFC, we recorded the PFC field potential with brief 250-Hz train stimulation (1, 3, 5, 7, and 9 pulses) of pdCA1 or vCA1 in anesthetized rats. Analysis of the gamma-band (40-100 Hz) power revealed stimulation-evoked gamma oscillation in the pdCA1-PFC, but not in the vCA1-PFC. These results indicate that these pathways have different responses to train stimulation. The function of the pdCA1-PFC may differ from that of the vCA1-PFC, a well-known hippocampus-PFC pathway.

Anesthesia↗

Neuronal activity in the substantia nigra in the anaesthetized rat has fractal characteristics. Evidence for firing-code patterns in the basal ganglia.

Current models of the basal ganglia assume a firing-rate code for information processing. We have applied five complementary computing methods to assess firing patterns in 188 cells of the substantia nigra in the anaesthetized rat. Fractal firing activity was found in 100% of nigral cells projecting to the superior colliculus, in 51% of cells projecting to the thalamus and in 33% of cells projecting to the pedunculopontine nucleus, but was practically absent in dopaminergic nigrostriatal neurons (3%). The finding of fractal firing patterns may lead to a better understanding of the normal operational mode and pathological manifestations of the basal ganglia.

Anesthesia↗

Differential regional metabolism of glucagon in anesthetized pigs.

Glucagon metabolism under basal (endogenous) conditions and during intravenous glucagon infusion was studied in anesthetized pigs by use of midregion (M), COOH-terminal (C), and NH2-terminal (N)-RIAs. Arteriovenous concentration differences revealed a negative extraction of endogenous glucagon immunoreactivity across the portal bed (-35.4 +/- 11.0, -40.3 +/- 9.6, -35.6 +/- 16.9%, M-, C-, N-RIA, respectively), reflecting net secretion of pancreatic glucagon and intestinal glicentin and oxyntomodulin, but under exogenous conditions, a net extraction occurred (11.6 +/- 3.6 and 18.6 +/- 5.7%, C- and N-RIA, respectively). Hindlimb extraction of endogenous (17.4 +/- 3.7%, C-RIA) and exogenous (29.1 +/- 4.8 and 19.8 +/- 5.1%, C- and M-RIA) glucagon was detected, indicating M and C cleavage of the molecule. Renal extraction of glucagon was detected by all assays under endogenous (19.4 +/- 6.7, 33.9 +/- 7.1, 29.5 +/- 6.7%, M-, C-, N-RIA) and exogenous conditions (46.9 +/- 4.8, 46.4 +/- 6.0, 47.0 +/- 7.7%; M-, C-, N-RIA), indicating substantial elimination of the peptide. Hepatic glucagon extraction was undetectable under basal conditions and detected only by M-RIA (10.0 +/- 3.8%) during glucagon infusion, indicating limited midregional cleavage of the molecule. The plasma half-life determined by C- and N-RIAs (2.7 +/- 0.2 and 2.3 +/- 0.2 min) were similar, but both were shorter than when determined by M-RIA (3.2 +/- 0.2 min, P < 0.02). Metabolic clearance rates were similar regardless of assay (14.4 +/- 1.1, 13.6 +/- 1.7, 17.0 +/- 1.7 ml x kg-1 x min-1, M-, C-, N-RIA). Porcine plasma degraded glucagon, but this was not significantly affected by the dipeptidyl peptidase IV (DPP IV) inhibitor valine-pyrrolidide, and in anesthetized pigs, glucagon's metabolic stability was unchanged by DPP IV inhibition. We conclude that tissue-specific metabolism of glucagon occurs, with the kidney being the main site of removal and the liver playing little, if any, role. Furthermore, valine-pyrrolidide has no effect on glucagon stability, suggesting that DPP IV is unimportant in glucagon metabolism in vivo, in contrast to its significant role in the metabolism of the other proglucagon-derived peptides and glucose-dependent insulinotropic polypeptide.

Anesthesia↗