PubMed Health⌕ Search

PubMed · 11599548

A modified protocol for quantitative fit testing using the PortaCount.

Abstract

A modified quantitative fit testing method has been developed for testing half masks using the TSI PortaCount respirator fit tester. This approach focuses on shortening the time for each exercise during fit testing; however, the shortened protocol is applied only to the very good-fitting masks. For marginal-fitting masks, the testing is carried out according to the full Occupational Safety and Health Administration (OSHA) respiratory protection standard (29CFR1910.134).(1) The shortened protocol (currently not approved by OSHA) still uses all the exercises required by the OSHA standard but for a shorter time (30 seconds [s] for each exercise instead of the usual 60 s). How good the fit has to be to qualify for a shortened exercise is determined by the statistical analysis of a large data set containing pass and fail fit-test data. The statistical analysis involves calculating the sensitivity and specificity of the pass and failed fit tests on half masks. From this analysis, a multiplication factor (K) to the OSHA pass/fail criterion was developed. For a respirator to undergo the shortened protocol, the fit factor obtained during any exercise must be K times the OSHA pass/fail criterion of 100 for half masks. Hence, this approach is more conservative than fit testing protocols that involve shortened exercises regardless of the fit. Nevertheless, this approach still saves time without compromising the accuracy of the fit test expressed in terms of sensitivity and specificity. For the existing data, 85 percent of the fit tests would have been performed according to the faster test protocol while only 15 percent of the tests would have been tested according to the full-length OSHA test protocol.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Sreenath, J Weed, T Church. 2001. A modified protocol for quantitative fit testing using the PortaCount.. https://doi.org/10.1080/104732201300367245

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Acute pulmonary embolism emergency. Confirming diagnosis, administering heparin, begin thrombolysis].

In suspected acute pulmonary embolism, the measurement of the d-dimer is now an established screening method. Further diagnostic measures include the electrocardiogram, echocardiography and conventional chest radiography, as well as the analysis of blood gases. The specific demonstration of a pulmonary embolism is achieved with a helical CT of the thorax, pulmonary angiography and ventilation/perfusion scanning. Apart from continuous (infusion) of unfractionated heparin, the low molecular weight heparins also are of potential value in the treatment of pulmonary embolism. A larger percentage of patients benefit from the use of fibrinolytic agents than was previously thought, so that the indication for fibrinolytic therapy should not be made dependent on the presence of hemodynamic instability.

Decision Trees↗

Diagnostic criteria for Parkinson's disease.

The diagnosis of Parkinson's disease is not easy. Developments in basic research have indicated pathophysiological links among parkinsonian syndromes that are still classified as independent entities. On the other hand, genetic studies are dividing forms that fit into the clinical diagnosis of Parkinson's disease. The diagnostic criteria used in current practice are by no means satisfactory, but cannot yet be replaced by new comprehensive criteria based on laboratory evidence.

Decision Trees↗

Application of decision trees to the analysis of soil radon data for earthquake prediction.

Different regression methods have been used to predict radon concentration in soil gas on the basis of environmental data, i.e. barometric pressure, soil temperature, air temperature and rainfall. Analyses of the radon data from three stations in the Krsko basin, Slovenia, have shown that model trees outperform other regression methods. A model has been built which predicts radon concentration with a correlation of 0.8, provided it is influenced only by the environmental parameters. In periods with seismic activity this correlation is much lower. This decrease in predictive accuracy appears 1-7 days before earthquakes with local magnitude 0.8-3.3.

Decision Trees↗