PubMed Health⌕ Search

PubMed · 11637686

[Not Available].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Lafont, C Van Robaeys. 1988. [Not Available].. https://pubmed.ncbi.nlm.nih.gov/11637686/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel insights into tomato leaf curl New Delhi virus introduction and evolution in Southeastern France using an advanced long-read sequencing workflow.

The Mediterranean population of tomato leaf curl New Delhi virus (ToLCNDV-ES) is characterized by a high genetic uniformity, distinguishing it from its Asian counterparts. ToLCNDV-ES is thought to have a monophyletic origin, likely resulting from a single recombination event, prior to its spread throughout the Mediterranean region. Following its first detection in southeastern France in 2020, ToLCNDV-ES re-emerged in France in 2022. Our analysis based on advanced long-read sequencing, circular DNA profiling, and phylogeny indicates both local persistence of French ToLCNDV-ES and multiple independent introduction events. Signatures of positive selection were identified in French ToLCNDV-ES populations, whereas no clear evidence of recombination was found. Bayesian time-structured phylogenetic analyses suggest that introductions in France occurred between 2018 and 2021 from the major ToLCNDV-ES clade, while several Italian ToLCNDV-ES isolates diverged prior to the virus introduction in the Mediterranean basin. Overall, this study demonstrates the value of an optimized long-read sequencing approach for resolving circular DNA virus diversity, and sheds light on the complex evolutionary history of ToLCNDV-ES in the Mediterranean Basin, particularly in southeastern France.

France↗

Half-life determination of 88Y and 89Sr.

Half-life measurements have been carried out at LNHB for 88Y using a 4pi gamma-ionisation chamber and for 89Sr using a proportional counter. The determined half-life values and associated standard uncertainties are 106.63 +/- 0.05 d for 88Y and 50.65 +/- 0.05 d for 89Sr, being consistent with relevant values reported in literature. Based on the present results and relevant literature values revised recommended half-life values and associated standard uncertainties are proposed, viz. 106.626 +/- 0.021 d for 88Y and 50.57 +/- 0.03 d for 89Sr.

France↗