PubMed Health⌕ Search

PubMed · 11639868

[Not Available].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C R Grund. 1993. [Not Available].. https://pubmed.ncbi.nlm.nih.gov/11639868/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Capillary electrophoresis and its application in the clinical laboratory.

Over the past 10 years, capillary electrophoresis (CE) is an analytical tool that has shown great promise in replacing many conventional clinical laboratory methods, especially electrophoresis and high performance liquid chromatography (HPLC). The main attraction of CE was that it was fast, used small amounts of sample and reagents, and was extremely versatile, being able to separate large and small analytes, both neutral and charged. Because of this versatility, numerous methods for clinically relevant analytes have been developed. However, with the exception of the molecular diagnostic and forensic laboratories CE has not had a major impact. A possible reason is that CE is still perceived as requiring above-average technical expertise, precluding its use in a laboratory workforce that is less technically adept. With the introduction of multicapillary instruments that are more automated, less technique-dependent, in addition to the availability of commercial and cost effective test kit methods, CE may yet be accepted as a instrument routinely used in the clinical laboratories. Thus, this review will focus on the areas where CE shows the most potential to have the greatest impact on the clinical laboratory. These include analysis of proteins found in serum, urine, CSF and body fluids, immunosubstraction electrophoresis, hemoglobin variants, lipoproteins, carbohydrate-deficient transferrin (CDT), forensic and therapeutic drug screening, and molecular diagnostics.

Chemistry, Clinical↗

Development of a sensitive high-performance liquid chromatography method for the detection of 667 COUMATE in vivo.

Steroid sulphatase inhibitors which decrease or prevent the biosynthesis of oestrogens, potentially have an important role in the treatment of breast cancer in postmenopausal women. The non-steroidal sulphatase inhibitor 667 COUMATE has been shown to be active both in vitro and in vivo. The pharmacokinetics of this drug have not been investigated. In preparation for the clinical evaluation of this agent, a sensitive and robust reversed phase high-performance liquid chromatography (HPLC) method was developed for the detection of 667 COUMATE in biological fluids. The sulphatase inhibitor was extracted from plasma with diethyl ether and separated from putative metabolites and endogenous plasma components with a C3-phenyl column. Using this method an extraction efficiency of 76+/-5% and a limit of detection of less than 0.1 ng/ml was achieved. The stability of this agent was investigated under different pH conditions and during storage in plasma at room temperature or -20 degrees C. 667 COUMATE was found to be stable when stored in acidified plasma (pH 4.5) at -20 degrees C. In conclusion, the HPLC method developed is a reproducible and sensitive assay that will enable quantitation of the potent non-steroidal sulphatase inhibitor 667 COUMATE in biological fluids in the forthcoming Phase I clinical trial.

Chemistry, Clinical↗

Stability studies of ubiquinol in plasma.

BACKGROUND: Ubiquinol is a sensitive redox marker in the first line of the antioxidative defence mechanism and is increasingly being measured in oxidation studies. Because of its apparent instability during storage and processing, we compared various storage conditions. METHOD: Blood was collected from three volunteers into tubes containing EDTA; it was then separated at 4 degrees C and cryopreserved with saccharose (final concentration 6 g/L). Aliquots were stored with or without glutathione or butylated hydroxytoluene at -20 degrees C and -80 degrees C. RESULTS AND CONCLUSION: Ubiquinol in samples stored at -20 degrees C was not stable; however, it was stable when stored at -80 degrees C, even without addition of antioxidant. By contrast, alpha-tocopherol was stable under all conditions studied.

Chemistry, Clinical↗