PubMed Health⌕ Search

PubMed · 11707048

Atrioventricular interval optimization and exercise tolerance.

Abstract

Modern pacemakers offer many programming options regarding the AV interval including the ability to vary AV intervals depending on whether atrial activity is paced or spontaneous and to shorten AV intervals with increasing rates. To determine if optimization of these features improves exercise tolerance, 14 patients with intact sinus node function and AV block treated with dual chamber pacemakers were enrolled in a randomized double-blind crossover trial. Doppler echocardiographic measurements of cardiac index and mitral flow were assessed over a range of programmable AV intervals at rest to determine each patient's optimal AV interval. Eleven patients completed serial graded exercise tests with spiroergometry after randomly programming the AV interval three ways in a crossover manner: fixed AV interval = 150 ms without rate adaptation (150/Fixed), fixed AVinterval = 150 ms with rate adaptation (150/R), or optimized AV interval with rate adaptive AV interval shortening (optimized/R). Exercise capacity was determined by maximum oxygen uptake. Ten men and four women, age 64 +/- 8 years, were enrolled. At rest, optimization of the AVintervalimproved the cardiac index by 21% (P < 0.001) and mitral flow by 13.4% (P < 0.001) when compared to least-favorable AV intervals. During exercise, no differences in maximum heart rates were noted. Maximum oxygen uptake was increased in both groups with rate adaptive AVinterval shortening when compared tofixed AVinterval without rate adaptation: 13.9% (adjusted P < 0.04) and 14.6% (adjusted P < 0.02) in optimized/R and 150/R, respectively. No differences were noted between optimized/R and 150/R. In conclusion, rate adaptive AV interval shortening improved exercise tolerance independent of changes in heart rate. However, optimization of the AV interval with Doppler echocardiography at rest did not further improve exercise capacity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Khairy, M Talajic, M Dominguez, J C Tardif, M Juneau, L Lavoie, D Roy, M Dubuc. 2001. Atrioventricular interval optimization and exercise tolerance.. https://doi.org/10.1046/j.1460-9592.2001.01534.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of the optimal region for interaliasing distance measurement for flow regurgitant rate calculation: a fluid simulation study.

BACKGROUND: Color Doppler imaging of the convergent region is promising for quantifying valvular regurgitation. Nevertheless, proximal isovelocity surface area method has limitations. We sought to determine the optimal localization to measure the most precise flow rate using a new approach: the interaliasing distance. METHODS: A finite volume-based program was used to perform simulations in unsteady flow conditions. Different instantaneous flow rates, leaflet angles, and orifice sizes were tested reproducing physiologic conditions. Relative difference between actual and interaliasing distance flow rate was calculated for each configuration. RESULTS: The relationship between the relative error and the aliasing velocity location was described by a third-order polynomial equation. The magnitude of relative error is a function of the flow rate, orifice size, and leaflet angle. CONCLUSION: The optimal distance from the orifice to measure the interaliasing distance was when the closer aliasing was between 4 and 8 mm from the orifice.

Atrial Function↗

A technical approach to optimized atrial recognition in the ICD: the intrathoracic six-channel farfield ECG.

Present-day ICD systems offer the possibility to reconstruct an intrathoracic 6-lead ECG (IT-ECG), using the defibrillator coils in the right ventricle and superior vena cava and the left-laterally positioned ICD as electrodes according to Einthoven and Goldberger. The aim of this study was to assess the feasibility of (1). automated P wave recognition in the IT-ECG without an additional atrial electrode as the basis of AV synchronous ventricular pacing (VDD) and for improved differentiation between supraventricular tachyarrhythmias and, (2). the automated detection of pacing evoked atrial potentials (EAP) in dual chamber ICDs as the basis for atrial "autocapture"pacing systems. In 27 patients during ICD implanation intraoperatively, the IT-ECG was digitally recorded. A recently established algorithm for automatic P wave and EAP detection correctly identified 1663/1672 (99.5%) P waves (oversensing rate 0.6%) and 543/554 (98.0%) EAP (no oversensing). During subthreshold atrial stimulation, 405/412 (98.3%) P waves were correctly identified (oversensing due to pacemaker spikes, n = 421, without subsequent EAP, 1.9%,n = 8). During stimulated ventricular tachycardia in 26/27 patients retrograde P wave or AV dissociation were identified. The 6-lead IT-ECG, easily implementable in ICD systems, is a diagnostic tool providing reliable information about atrial activation, serving as a basis for VDD pacing in single chamber ICD systems, allowing reliable EAP recognition that enables atrial "autocapture"pacing in dual chamber ICDs, and improves the differentiation between supraventricular and ventricular tachycardia.

Atrial Function↗