PubMed Health⌕ Search

PubMed · 11731050

Contrast agent stability: a continuous B-mode imaging approach.

Abstract

The stability of contrast agents in suspensions with various dissolved gas levels has not been reported in the literature. An in vitro investigation has been carried out that studied the combined effect of varying the acoustic pressure along with degassing the suspension environment. In this study, the contrast agents were introduced into suspensions with different oxygen concentration levels, and their relative performance was assessed in terms of decay rate of their backscatter echoes. The partial pressures of oxygen in those solutions ranged between 1.5 and 26 kPa. Two IV and one arterial contrast agents were used: Definity, Quantison, and Myomap. It was found that Quantison and Myomap released free bubbles at high acoustic pressure that also dissolved faster in degassed suspensions. The backscatter decay for Definity did not depend on the air content of the suspensions. The destruction of bubbles was dependent on acoustic pressure. Different backscatter performance was observed by different populations of bubbles of the last two agents. The physical quantity of "overall backscatter" (OB) was defined as the integral of the decay rate over time of the backscatter of the contrast suspensions, and improved significantly the understanding of the behaviour of the agents. A quantitative analysis of the backscatter properties of contrast agents using a continuous imaging approach was difficult to achieve. This is due to the fact that the backscatter in the field of view is representative of a bubble population affected by the ultrasound (US) field, but this bubble population is not representative of the contrast suspension in the whole tank. Single frame insonation is suggested to avoid the effects of decay due to the ultrasonic field, and to measure a tank-representative backscatter. The definition of OB was useful, however, in understanding the behaviour of the agents.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Sboros, C M Moran, S D Pye, W N McDicken. 2001. Contrast agent stability: a continuous B-mode imaging approach.. https://doi.org/10.1016/s0301-5629(01)00440-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement.

New sterilization methods for human bone allografts may lead to alterations in bone mechanical properties, which strongly influence short- and medium-term outcomes. In many sterilization procedures, bone allografts are subjected to gamma irradiation, usually with 25 KGy, after treatment and packaging. We used speed-of-sound (SOS) measurements to evaluate the effects of gamma irradiation on bone. All bone specimens were subjected to the same microbial inactivation procedure. They were then separated into three groups, of which one was treated and not irradiated and two were exposed to 10 and 25 KGy of gamma radiation, respectively. SOS was measured using high- and low-frequency ultrasound beams in each orthogonal direction. SOS and Young modulus were altered significantly in the three groups, compared to native untreated bone. Exposure to 10 or 25 KGy had no noticeable effect on the study variables. The impact of irradiation was small compared to the effects of physical or chemical defatting. Reducing the radiation dose used in everyday practice failed to improve graft mechanical properties in this study.

Acoustics↗

Objective and subjective evaluation of the acoustic comfort in classrooms.

The acoustic comfort of classrooms in a Brazilian public school has been evaluated through interviews with 62 teachers and 464 pupils, measurements of background noise, reverberation time, and sound insulation. Acoustic measurements have revealed the poor acoustic quality of the classrooms. Results have shown that teachers and pupils consider the noise generated and the voice of the teacher in neighboring classrooms as the main sources of annoyance inside the classroom. Acoustic simulations resulted in the suggestion of placement of perforated plywood on the ceiling, for reduction in reverberation time and increase in the acoustic comfort of the classrooms.

Acoustics↗

Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

OBJECTIVE: To characterize the ultrasound fields produced by a cohort of transducers from a single manufacturer via hydrophone and Schlieren technology. DESIGN: Descriptive study. SETTING: Measurement laboratory. PARTICIPANTS: Seven same-model ultrasound transducers from a single manufacturer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Effective radiating area (ERA), total power, spatial average intensity (SAI), beam nonuniformity ratio (BNR), and Schlieren beam widths at 1.0 and 3.3 MHz. RESULTS: Values for ERA (1.0 MHz range, 3.62-4.38 cm(2); 3.3 MHz range, 3.74-4.76 cm(2)), total power (1.0 MHz range, 5.0-5.6 W; 3.3 MHz range, 4.7-5.7 W), SAI (1.0 MHz range, 1.2-1.4 W/cm(2); 3.3 MHz range, 1.0-1.5 W/cm(2)), and BNR (1.0 MHz range, 2.79-5.85; 3.3 MHz range, 2.51-4.56) fell within manufacturer's specifications and U.S. Food and Drug Administration (FDA) regulations. Schlieren analysis showed significantly larger beam widths at 3.3 MHz compared with 1.0 MHz and a large degree of variability in the ultrasound fields generated by the different transducers. There were no significant correlations between beam widths and ERA values. CONCLUSIONS: ERA and total power values in a test cohort exist within a range that met FDA regulations. Individual variability in ERA and total power resulted in 50% variability in SAI. This variability may help explain previous reports of heating differences between transducers.

Acoustics↗