PubMed · 11740455
[Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels].
Abstract
PURPOSE: The absorbed dose during clinical examinations of the head, thorax, abdomen and pelvis performed with a single-slice CT scanner and a new multi-slice CT system was measured and compared. Technical parameters, defined at installation and memorized on the two CT machines relate to a standard-sized patient and were considered the reference standard. Our experimental data were also been compared with the Diagnostic Reference Levels (D.L. 26/5/2000 n.187, Annex V). MATERIAL AND METHODS: We compared the performance of a multi-slice GE LightSpeed QX/i ADVANTAGE to that of a single-slice GE ProSpeed SX. The radiation beam profiles were measured at isocenter using a phosphor plate. Dose measurements were performed, according to the EUR 16262 EN Guidelines, with a 10-cm long CT pencil ionisation chamber and two PMMA phantoms (CEI EN 61223-2-6) for head and body respectively. RESULTS: The obtained (normalised and weighted) computed tomographic dose index (nCTDIW) values were systematically higher for the multi-slice system (up to 36%) and the dose-length product (DLP) values on the multi-slice scanner exceeded the equivalent single-slice DLP values. The values were, however, always lower than DRLs, except in the case of the head multi-slice protocol, the technical parameters of which need to be improved. Our results allowed moreover to calibrate the automatic dose evaluation system of the multi-slice system, which systematically underestimated DLP values. DISCUSSION AND CONCLUSIONS: The comparison showed that the multi-slice scanner delivers a higher dose compared to the single-slice scanner. This is due to the radiation beam profile which is wider than the total active detector width, to the shorter focal spot-to-isocenter distance and to the effective scan length, which is longer than the nominal irradiated volume because the reconstruction algorithm of a multi-slice helical CT image requires the projection data from all detector rows. Nevertheless, the technology of new CT systems equipped with a multiple row detectors array can improve the protection of the patient thanks to very short irradiation time (less than 1 s) and reduced current values. In order to optimize the dose to the patient some acquisition parameters have been adjusted for head examinations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
L Moro, A Bolsi, M Baldi, G Bertoli, D Fantinato. 2001. [Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels].. https://pubmed.ncbi.nlm.nih.gov/11740455/
Cite the original work for its findings. Save a collection to share your selection of sources.