PubMed Health⌕ Search

PubMed · 11745577

Hydroxyapatite coating on titanium by thermal substrate method in aqueous solution.

Abstract

A new hydrocoating method (the thermal substrate method) is proposed for coating calcium phosphates such as hydroxyapatite (HA), on titanium substrates in an aqueous solution. Several factors (e.g., the type of ion source, the heating time and temperature, and the surface roughness of the substrate) affected the characteristics of the precipitate formed by this method. The solution used included 3 mmol dm(-3) Ca(H(2)PO(4))(2) and 7 mmol dm(-3) CaCl(2), and its pH was adjusted to 6.5. The experimental studies were conducted under the following conditions: temperature 45-160 degrees C, heating time 10-20 min, and surface roughness of substrate #120-#2000 grid ground using energy paper. A high quality of precipitate, whose predominant component was HA, was obtained on titanium substrates by the thermal substrate method in an aqueous solution. No significant difference in the precipitates was found with the type of ion source. The amount of HA precipitate increased with increasing temperature and with increasing heating time. The features of the precipitate were different, depending on the surface roughtness of the substrate: HA regularly nucleated along the grooves of the rough surface (#120 and #400 grid), and in the case of the fine surface (#1200-#2000 grid), a uniform precipitation occurred.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kensuke Kuroda, Ryoichi Ichino, Masazumi Okido, Osamu Takai. 2002. Hydroxyapatite coating on titanium by thermal substrate method in aqueous solution.. https://doi.org/10.1002/jbm.10002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

General properties of silated hydroxyethylcellulose for potential biomedical applications.

The general properties of hydroxyethylcellulose (HEC) grafted with 3-glycidoxypropyltrimethoxysilane (GPTMS) or 3-glycidoxypropylmethyldiethoxysilane (GPDMS) were studied for potential biomedical applications. The graft involved a Williamson reaction between the free hydroxyl function of HEC and the epoxy function of the two silanes. As the grafted silanes are in ionic form (sodium silanolate), this product remains in gel form at basic pH (>12.3) in aqueous solution. When pH decreases, sodium silanolate is transformed into silanol (2 or 3 silanol functions are carried by silicon, depending on the silane grafted). The silanols interreact, and the gel is transformed into a cross-linking form at room or body temperature. Studies were conducted to optimise this product for specific uses. Steam sterilization was used to compare self-hardening as a function of the silane grafted. Our previous work indicated that HEC grafted with GPTMS has good reactivity, but requires high pH for dissolution, whereas dissolution occurs at lower pH with GPMDS. The rate of silanol condensation for silated HEC was then determined as a function of pH, temperature, type of silane, and the percentage grafted. Condensation rates were ascertained by the viscosity method, and gels were neutralized by different solutions to obtain buffered forms at various pH. The time required to obtain 10(5) mPa x s, with an initial state of 2500 mPa x s, was then calculated. Condensation was catalysed in acid or basic medium at a lower rate at pH 5.5-6.5, and a temperature rise increased the condensation rate, regardless of the pH or silane studied. Silanetriol was more reactive than silanediol. However, as HEC lost considerable viscosity after sterilization, further studies will be conducted to develop new polysaccharides grafted with silane.

Biocompatible Materials↗

Biocompatibility studies on biodegradable polyester-based composites of human osteoblasts: a preliminary screening.

A series of biodegradable composites with natural hydroxyapatite, designed for possible use in orthopedics applications, were preliminarily screened for biocompatibility by employing primary cultures of human osteoblasts in a direct contact method. The cells were seeded at low density onto the materials under investigation and allowed to grow for 2 weeks. They then were analyzed for morphology, proliferation, viability, alkaline phosphatase activity (AP), osteocalcin (OC) production, and extracellular matrix mineralization. The results showed that all materials have good biocompatibility. Cell viability tests demonstrated that in all cases the values were comparable to the control, and the addition of hydroxyapatite always resulted in an enhancement of performance with respect to the plain polymer. AP and OC analysis confirmed that all composites allowed the expression of phenotypic markers. Scanning electron microscopy provided direct evidence of intense cell adhesion and proliferation on the tested materials.

Biocompatible Materials↗

Induction of c-fos and c-jun protooncogenes expression by formaldehyde-releasing and epoxy resin-based root-canal sealers in human osteoblastic cells.

An important requirement for a root-canal sealer is biologic compatibility; most evaluations have focused on general toxicological and local tissue irritating properties. There is only scant information about mutagenicity or carcinogenicity testing for root-canal sealer. It has been shown that c-fos and c-jun are induced rapidly by a variety of chemical and physical stimuli. Numerous works have extensively investigated the induction mechanisms of c-fos and c-jun protooncogenes by these agents; however, little is known about the induction of cellular signaling events and specific gene expression after cell exposure to root-canal sealers. Therefore, we used osteoblastic cell line U2-OS to examine the effect of zinc-oxide eugenol-based (N2 and Endomethasome), epoxy resin-based (AH Plus), and calcium hydroxide-based (Sealapex) root-canal sealers on the expression of c-fos and c-jun protooncogenes to understand in more detail the molecular mechanisms of root-canal sealer-induced genotoxicity. The cytotoxicity decreased in an order of N2 > Endomethasome > AH Plus > Sealapex. In addition, N2, Endomethasome, and AH Plus rapidly induced c-jun and c-fos mRNA levels in cells. However, Sealapex did not induce c-jun and c-fos mRNA expression at detectable levels all time points. Taken together, persistent induction of c-jun and c-fos protooncogenes by formaldehyde-releasing and epoxy resin-based root-canal sealers may be distributed systemically via apex to cause some unexpected adverse effects on human beings. These data should be taken into consideration when choosing a root-canal sealer.

Biocompatible Materials↗