Performance evaluation of QuantiBRITE phycoerythrin beads.

Abstract

BACKGROUND: The performance of QuantiBRITE phycoerythrin (PE) beads to standardize quantitation in terms of antibodies bound per cell (ABC) was evaluated by measuring precision, variation across multiple instruments, and variation across time. METHODS: For CD4 quantitation, whole blood was stained with a two-color CD4 reagent using a no-wash/no-lyse format. For CD69 quantitation, whole blood was activated with either phorbol myristate acetate (PMA) or CD3 beads and then stained with a three-color CD69 reagent using a lyse-no-wash format. RESULTS: Across 20 normal donors, the mean CD4 ABC was 51,000. Within-assay precision on quantitation of CD4 ABC on T cells had a coefficient of variance (CV) of <1.0%. Across multiple flow cytometers, quantitation of CD4 ABC had a CV of <5.0%. Within-donor CV on CD4 ABC on 20 donors across 2 months ranged from 1.3% to 3.2%. Within-assay precision on quantitation of CD69 on T cells activated with either PMA or CD3 beads had a CV of <3.0%. Within-donor CV of CD69 ABC across 1 month ranged from 2% to 18% on PMA-activated samples and from 7% to 24% on CD3 bead-activated samples. CONCLUSIONS: Our results indicate that the QuantiBRITE PE beads provide a useful tool for standardized analysis across labs. When used in conjunction with 1:1 conjugates of PE-to-monoclonal antibody, the QuantiBRITE PE beads provide a simple yet robust means of quantitating expression levels in terms of ABC.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K K Pannu, E T Joe, S B Iyer. 2001-12-01. Performance evaluation of QuantiBRITE phycoerythrin beads.. https://doi.org/10.1002/1097-0320(20011201)45%3A4%3C250%3A%3Aaid-cyto10021%3E3.0.co%3B2-t

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ZrO&#x2082;@C-based colorimetric/photothermal dual-mode immunosensor coupled with a novel monoclonal antibody for quantification of Aspergillus ochraceus biomass.

Aspergillus ochraceus contaminates agricultural products and produces nephrotoxic, carcinogenic ochratoxin A (OTA), posing severe food safety hazards. A dual-signal lateral flow immunochromatographic assay (dLFIA) based on ZrO&#x2082;@C nanoprobes was established for quantitative detection of A. ochraceus biomass. A novel monoclonal antibody (mAb 4B4) was prepared as the capture antibody to immobilize A. ochraceus mycelial lysate antigen on the test line, and a rabbit polyclonal antibody (pAb G2801) as the detection antibody to modify ZrO&#x2082;@C composites (synthesized via UiO-66 pyrolysis) into 200&#xa0;nm colorimetric/photothermal nanoprobes. This dLFIA achieved limits of detection of 0.164&#xa0;&#x3bc;g/mL (colorimetric) and 0.517&#xa0;&#x3bc;g/mL (photothermal). This efficient and reliable method allows quantitative analysis of A. ochraceus biomass, which is suitable for routine monitoring of fungal contamination in agro-food matrices.

Antibodies, Monoclonal↗

Rituximab for lymphoproliferative disease prior to haematopoietic stem cell transplantation for X-linked severe combined immunodeficiency.

Lymphoproliferative disease (LPD) is a complication of congenital and acquired immunodeficiency states. There are a number of treatment options for LPD arising after haematopoietic stem cell or solid organ transplantation including reduction of immunosuppression, targeted therapies, such as the anti-CD20 monoclonal antibody, rituximab, and EBV specific cytotoxic lymphocytes. Treatment of LPD in children with congenital immunodeficiency syndromes remains unsatisfactory and is associated with a high mortality rate. We recently managed an infant found to have polymorphic LPD concurrent with X-linked severe combined immunodeficiency (SCID). Haematopoietic stem cell transplantation (HSCT) had to be deferred because of progressive LPD. Treatment with rituximab resulted in regression of the LPD following which the patient received a 5/6 HLA matched umbilical cord blood (UCB) transplant. The patient remains well 20 months following transplantation. Rituximab treatment may have a useful role in the control of LPD associated with congenital immunodeficiency prior to HSCT.

Antibodies, Monoclonal↗

Response to rituximab in a child with neuroblastoma and opsoclonus-myoclonus.

Opsoclonus-myoclonus (OM) is a paraneoplastic syndrome of probable autoimmune origin. Despite current therapies aimed at decreasing autoantibody formation, OM is difficult to control and may impact long-term neurologic outcome. We present a case of a 19-month-old patient who initially presented with OM, neuroblastoma and a constitutional cytogenetic abnormality t(5;12)(q11.2;q15). The patient's OM was recalcitrant to conventional therapies, but showed significant improvement following treatment with rituximab.

Antibodies, Monoclonal↗