Telepathology.

Abstract

The development of a Queensland-wide videoconferencing network provided an opportunity to develop telepathology. In 1999, weekly videoconferences began with remote laboratories and clinical staff in four peripheral hospitals and the Royal Brisbane Hospital and in 2000 biweekly videoconference pathology grand rounds started across Queensland with up to six sites, from Cairns to the Gold Coast, joining in or presenting. The average number of sites connected was 3.0 in 1998, 3.5 in 1999, 4.4 in 2000 and 4.5 in 2001. Problems included the complexity of the system, timing and need for bookings, coordination of presenters and presentations, and the time needed to organize sessions, set up linkages, advertise sessions and attend the telepathology conference. Successful meetings have been associated with well prepared cases, time for discussion, attendance by all sites, timeliness of cases and responses, and the presence of experts to respond to questions, as well as effective linkages and trouble-free hardware. Future needs include better infrastructure and trained staff to coordinate the linkages and presentations. Telepathology has an important part to play in the provision of cost-effective medical care in Queensland.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Faoagali, W Coles, L Price, D Siebert. 2001. Telepathology.. https://doi.org/10.1258/1357633011937209

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Practical assessment of the display performance of radiology workstations.

The performance of 14 primary clinical display monitor workstations in use in the Radiology Department of a large acute NHS Trust was assessed using the methods and guidelines described by the American Association of Physicists in Medicine Task Group 18. Tests undertaken included the measurement of ambient light, display uniformity, luminance ratio, luminance response, maximum luminance and spatial resolution. Four display monitors failed to meet at least one of the test's guideline tolerances. In addition a number of display monitors were found to be operating at settings that might reduce their useful life span. These devices were either replaced or recalibrated by the installers, or were subject to local adjustment to ensure applicable standards were met. Consequently the study suggests that quality assurance testing of display monitors used for image reporting is necessary and valuable to ensure that images are viewed at an appropriate standard.

Computer Terminals↗