PubMed Health⌕ Search

PubMed · 11755707

Biomolecule-sensitive hydrogels.

Abstract

Stimuli-sensitive hydrogels have attracted considerable attention as intelligent materials in the biochemical and biomedical fields, since they can sense environmental changes and induce structural changes by themselves. In particular, biomolecule-sensitive hydrogels that undergo swelling changes in response to specific biomolecules have become increasingly important because of their potential applications in the development of biomaterials and drug delivery systems. This article provides an overview of the important and historical research regarding the synthesis and applications of glucose-sensitive hydrogels which exhibit swelling changes in response to glucose concentration. Enzymatically degradable hydrogels and antigen-sensitive hydrogels are also described in detail as protein-sensitive hydrogels that can respond to larger biomolecules. The synthetic strategies of other biomolecule-sensitive hydrogels are summarized on the basis of molecular imprinting and specific interaction. The biomolecule-sensitive hydrogels reviewed in this paper are expected to contribute significantly to the exploration and development of newer generations of intelligent biomaterials and self-regulated drug delivery systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Takashi Miyata, Tadashi Uragami, Katsuhiko Nakamae. 2002-01-17. Biomolecule-sensitive hydrogels.. https://doi.org/10.1016/s0169-409x(01)00241-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design and evaluation of novel blood incubation systems for in vitro hemocompatibility assessment of planar solid surfaces.

Success in the development of hemocompatible biomaterials depends on adequate equipment and procedures for standardized analysis of blood-materials interactions in vitro. In view of the limited standard of knowledge on that important aspect, two novel incubation systems were designed, built, and evaluated for the in vitro assessment of the hemocompatibility of planar solid surfaces: A screening setup was introduced for the comparison of up to 12 different samples. A perfusion setup was developed to model the directed blood flow in the vascular system during incubation by a recirculation circuit, allowing the variation of the wall shear rate at the sample surface. The incubation procedures utilized freshly drawn, heparinized whole human blood. Hemocompatibility in terms of selected aspects of coagulation, thrombogenicity, and immune responses was quantified through plasma levels of characteristic molecules (immunoassays), cell counting, and analysis of adherent cells and fibrin formation (scanning electron microscopy), respectively. Prevention of blood-air contact and mechanical stress, constant temperature and blood pH during incubation, and the suitable choice of reference materials were found to be crucial for reliable testing. Considering those requirements, screening and perfusion system both provided sensitive discrimination between a given set of planar solid surfaces. In conclusion, the suggested methods for an in vitro hemocompatibility assessment permit versatile, sensitive, and efficient analysis of important blood-material interactions despite the unavoidable variability of blood characteristics in different experiments.

Biocompatible Materials↗

Reduction of wear in total hip replacement prostheses by amorphous diamond coatings.

Wear-debris-induced periprosthetic bone loss and aseptic loosening is regarded as the main long-term problem of total hip replacements (THRs). In this study the amount of wear debris from articulating surfaces of THRs was reduced so as to be close to negligible by the use of high-quality amorphous diamond (AD) coatings deposited by pulsed plasma arc techniques. The wear rates determined in a commercial hip simulator for 15 million walking cycles (corresponding to about 15 years of clinical use) in serum lubrication were even 1,000,000 times lower than the clinical values for conventional THRs (polyethylene-metal or metal-metal pairs). Elimination of wear debris and good biomechanical performance should provide a substantial improvement of the clinical longevity of the THRs.

Biocompatible Materials↗

Adhesion of human leukocytes to biomaterials: an in vitro study using alkanethiolate monolayers with different chemically functionalized surfaces.

The adhesion of human leukocytes to self-assembled monolayers of well-defined surface chemistry was investigated in vitro. Polymorphonuclear (PMN) and mononuclear leukocytes were isolated from human blood by centrifugation techniques. The effect on adhesion of cell activation produced by pre-incubation of leukocytes with phytohemagglutinin (PHA) and phorbol 12-myristate 13-acetate (PMA) was also studied. Gold substrates were modified by treatment with alkanethiols with three different terminal chemical groups: COOH, OH, and CH(3). After incubation with the two subpopulations of leukocytes, the monolayers were washed, treated with fixative, stained with a Giemsa method, and observed by light microscopy to quantify the number of attached leukocytes. Comparative quantification of the density of leukocyte adhesion to the three types of self-assembled monolayers was determined. The hydrophobic surface expressing CH(3) was found to be the one that induced the highest adhesion density of leukocytes, both of PMN and mononuclear cells. In vitro activation of both mononuclear and PMN leukocytes further increased cell adhesion to the chemically defined monolayers that were used. This enhancement was higher for PHA-activated than for PMA-stimulated mononuclear cells, whereas PMA treatment of neutrophils resulted in a higher rate of adhesion of these cells than PHA stimulation.

Biocompatible Materials↗