PubMed Health⌕ Search

PubMed · 11767170

Honey as a candidate reference material for trace elements.

Abstract

The feasibility of producing and certifying new certified reference materials (CRMs) for trace elements in honey was investigated. Preliminary steps for preparation of candidate materials are performed at the Institute for Reference Materials and Measurements, Joint Research Centre of the European Commission (EC-JRC-IRMM). Two different types of honey, Acacia and Eucalyptus, were tested for determination of 10 trace elements. To each type of honey was added a given amount of high purity deionized water to obtain aqueous solutions with an acceptable degree of homogeneity which would require only minimal manipulation before analysis. Average values obtained for the trace elements by means of inductively coupled plasma-based techniques were as follows (in microg/ kg +/- SD): Acacia honey, As, 1.10+/-0.20; Cd, 0.328+/-0.035; Cr, 1.90+/-0.22; Cu, 67.0+/-5; Fe, 215+/-30; Hg, < 0.75; Mn, 82.1+/-6.2; Ni, 21.0 3.0; Pb, 2.30+/-0.25; Se, 9.10+/-1.2; Zn, 167+/-22; Eucalyptus honey, As, 5.99+/-0.10; Cd, 0.592+/-0.074; Cr, 1.50+/-0.07; Cu, 219 24; Fe, 1008+/-114; Hg, <0.75; Mn, 1009+/-51; Ni, 11.3+/-1.5; Pb, 5.00+/-0.40; Se, 5.60+/-0.91; Zn, 791+/-91. When these 2 pilot materials are ready, the certification project will be launched in full compliance with current rules set by EC-JRC-IRMM. If the project is successful, the new CRMs will be put primarily at the disposal of the National Reference Laboratories for trace elements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Forte, S D'Ilio, S Caroli. Honey as a candidate reference material for trace elements.. https://pubmed.ncbi.nlm.nih.gov/11767170/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Trace-level determination of pesticides in food using difficult matrix introduction-gas chromatography-time-of-flight mass spectrometry.

A procedure for the fully automated analysis of food samples by means of difficult matrix introduction-gas chromatography-time-of-flight mass spectrometry (DMI-GC-ToF MS) is discussed. After extraction, samples require very little clean-up and are injected in a micro- or micro-vial which is held in a liner. Next, the liner is placed in the injector and the contents of the vial are thermally desorbed and led directly to the capillary GC column. After GC-ToF MS analysis, the data are processed automatically using a peak deconvolution algorithm. The practicability of the procedure was demonstrated by analysing spiked grape and pineapple samples down to the 1-10 ng/g concentration level.

Food Analysis↗

Application of solid-phase microextraction for the determination of pyrethroid residues in vegetable samples by GC-MS.

A solid-phase microextraction (SPME) method has been developed for the determination of 7 pyrethroid insecticides (bifenthrin, lambda-cyhalothrin, permethrin, cyfluthrin, cypermethrin, fenvalerate, and tau-fluvalinate) in water, vegetable (tomato), and fruit (strawberry) samples, based on direct immersion mode and subsequent desorption into the injection port of a GC/MS. The SPME procedure showed linear behavior in the range tested (0.5-50 microg L(-1) in water and 0.01-0.1 mg kg(-1) in tomato) with r(2) values ranging between 0.97 and 0.99. For water samples limits of detection ranged between 0.1 and 2 microg L(-1 )with relative standard deviations lower than 20%. Detection limits for tomato samples were between 0.003 and 0.025 mg kg(-1) with relative standard deviations around 25%. Finally, the SPME procedure has been applied to vegetable (tomato) and fruit (strawberry) samples obtained from an experimental plot treated with lambda-cyhalothrin, and in both cases the analyte was detected and quantified using a calibration curve prepared using blank matrix. SPME has been shown to be a simple extraction technique which has a number of advantages such as solvent-free extraction, simplicity, and compatibility with chromatographic analytical systems. Difficulties with the correct quantification in a complex matrix are also discussed.

Food Analysis↗

Comparison of mass spectrometry-based electronic nose and solid phase microextraction gas chromatography-mass spectrometry technique to assess infant formula oxidation.

Two headspace techniques based on mass spectrometry detection (MS), electronic nose, and solid phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC/MS) were evaluated for their ability to differentiate various infant formula powders based on changes of their volatiles upon storage. The electronic nose gave unresolved MS fingerprints of the samples gas phases that were further submitted to principal component analysis (PCA). Such direct MS recording combined to multivariate treatment enabled a rapid differentiation of the infant formulas over a 4 week storage test. Although MS-based electronic nose advantages are its easy-to-use aspect and its meaningful data interpretation obtained with a high throughput (100 samples per 24 h), its greatest disadvantage is that the present compounds could not be identified and quantified. For these reasons, a SPME-GC/MS measurement was also investigated. This technique allowed the identification of saturated aldehydes as the main volatiles present in the headspace of infant milk powders. An isotope dilution assay was further developed to quantitate hexanal as a potential indicator of infant milk powder oxidation. Thus, hexanal content was found to vary from roughly 500 and 3500 microg/kg for relatively non-oxidized and oxidized infant formulas, respectively.

Food Analysis↗