PubMed Health⌕ Search

PubMed · 11771829

Solid-phase microextraction versus single-drop microextraction for the analysis of nitroaromatic explosives in water samples.

Abstract

This paper compares solid-phase microextraction (SPME) with a recently developed extraction method called single-drop microextraction (SDME) for the analysis of nitroaromatic explosives in water samples. The two techniques are examined in terms of procedure, chromatographic analysis and method performance. All practical considerations for both techniques are also reviewed. SPME requires dedicated apparatus and is relatively expensive, as the fiber's lifetime is limited. However, it has the advantages over SDME that it can be easily used for headspace analysis and has lower detection limits for all the target analytes. SDME requires more elaborate manual operations, thus affecting linearity and precision.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Psillakis, N Kalogerakis. 2001-12-14. Solid-phase microextraction versus single-drop microextraction for the analysis of nitroaromatic explosives in water samples.. https://doi.org/10.1016/s0021-9673(01)01417-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correlating sensory attributes to gas chromatography-mass spectrometry profiles and e-nose responses using partial least squares regression analysis.

Sensory scores for 15 attributes identified in soy sauce aroma by quantitative descriptive analysis were correlated with purge and trap gas chromatography-mass spectrometry (GC-MS) profiles and electronic nose (e-nose) responses using partial least squares (PLS) regression analysis. Highly predictive PLS models were obtained for every attribute based on whole GC-MS profiles. However, the predictability has been greatly improved in the models calculated from 20 selected peaks that showed higher contribution to each attribute in the first PLS analysis. Contrarily, except for alcoholic and fishy notes, predictability of PLS models calculated from e-nose responses was poor. The correlation between GC-MS profiles and e-nose responses was unsatisfactory due to high similarity in sensor responses.

Gas Chromatography-Mass Spectrometry↗

Chemical composition of the essential oil of Salvia multicaulis Vahl. var. simplicifolia Boiss. growing wild in Lebanon.

The essential oil of aerial parts of Salvia multicaulis Vahl. var. simplicifolia Boiss. (Lamiaceae) growing wild in Lebanon was obtained by hydrodistillation and was analysed by GC and GC-MS. 67 compounds constituting 95.2% of the oil were identified, the major components being alpha-copaene (8.0%), alpha-pinene (6.6%), myrtenol (5.7%), trans-sabinyl acetate (5.3%).

Gas Chromatography-Mass Spectrometry↗

Membrane-assisted solvent extraction of triazines, organochlorine, and organophosphorus compounds in complex samples combined with large-volume injection-gas chromatography/mass spectrometric detection.

The performance of the fully automated membrane-assisted solvent extraction was investigated for 47 environmental contaminants (among them 30 organochlorine compounds, 9 organophosphorus compounds, and 7 triazines). The extraction took place in a 20-mL headspace vial filled with the aqueous sample and containing a polypropylene membrane bag with 1 mL of cyclohexane as extractant. This device was handled by a multipurpose sampler, which enabled the sample to be mixed at a defined temperature with subsequent large-volume injection of the organic extract taken out of the membrane bag. After optimization of extraction parameters, the method was validated for the three compound classes, triazines and organochlorine and organophosphorus compounds, using spiked distilled water. Then, the extraction yield of these analytes from several complex samples such as a natural and a synthetic wastewater, a bacterial culture, and orange juice was determined and compared to a conventional liquid-liquid extraction. Furthermore, the possibility of reducing matrix interference by adding salt, methanol, or detergent during membrane-assisted solvent extraction was investigated.

Gas Chromatography-Mass Spectrometry↗