PubMed Health⌕ Search

PubMed · 11783620

Engineering microstructures to evaluate and replace trabecular bone.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J Hollister, P K Zysset, R E Guldberg, T M Chu, J W Halloran. 2001. Engineering microstructures to evaluate and replace trabecular bone.. https://doi.org/10.1007/978-1-4615-0651-5_19

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New approach to the urogynecological ultrasound examination.

OBJECTIVE: To evaluate a new system for the ultrasound evaluation of urethral mobility. STUDY DESIGN: We studied the structure of interpubic disc and found landmarks that can be used to align different images and set up an universal system of coordinates. The method for capturing and post-processing of the introital ultrasound examination is described. The urethra in its entire course is evaluated. Ten patients were examined and some important points at the interpubic disc and the urethra were traced to assess the reproducibility of the method. RESULTS: The mean intra-observer difference for x and y coordinates were 1.88 mm (S.D. 1.53) and 2.00 mm (S.D. 1.54), respectively. The inter-observer difference was 2.30 mm (S.D. 1.64) and 2.50 mm (S.D. 1.79), respectively for x and y coordinates. CONCLUSION: The method shows good inter- and intra-observer correlation and presents data that can be further used for biomechanical analysis.

Biomechanical Phenomena↗

Pullout test with three lumbar interbody fusion cages.

STUDY DESIGN: In vitro biomechanical testing was performed on 12 cadaveric human lumbar spines. OBJECTIVE: To determine the initial dislocation resistance, as quantified by the pullout force of three different cage designs. SUMMARY OF BACKGROUND DATA: Interbody cage devices frequently are used as stand-alone cages in the surgical treatment of degenerative conditions in the lumbar spine. In contrast to the wide clinical acceptance of interbody fusion cages, there are only a few biomechanical studies of posterior pullout trials. METHODS: Cylindrical threaded cages (Ray TFC Surgical Dynamics), bullet-shaped cages (Stryker), and newly designed rectangular titanium cages with an endplate anchorage device (Marquardt) were used for posterior interbody implants. For each device, the pullout test was performed in four specimens on both sides (L3-L4). RESULTS: In the pullout test, the Stryker cages required a median pullout force of 130 N (minimum, 100 N; maximum, 220 N), as compared with the higher pullout force of the Marquardt cages (median, 605 N; minimum, 450 N; maximum, 680 N), and the Ray cages (median, 945 N; minimum, 125 N; maximum, 2230 N). CONCLUSIONS: Differences in pullout resistance were noted depending on the cage design. A cage design with threads or a hook device provides superior stability, as compared with ridges. The initial pullout resistance was highest for the Ray cages and lowest for the Stryker cages.

Biomechanical Phenomena↗