PubMed Health⌕ Search

PubMed · 11784914

[Smallpox, an old foe].

Abstract

Smallpox has accompanied mankind for centuries, causing deaths and permanent lesions. Used in the past as a biological weapon during wars, it has come into focus again precisely because of this renewed possibility, although the disease has been eradicated in the Americas since 1971 and worldwide since 1977. Data gathered during the eradication campaigns show that the disease spread relatively slowly through close contacts between patients and susceptibles. Sub-clinical infection in non-vaccinated individuals was a rare event, and blockade vaccination surrounding new cases (as long as these cases were confirmed early) was able to prevent the disease from spreading in the community. Even with only one dose, vaccinated individuals rarely developed a serious case of the disease upon reinfection. The use of smallpox as a biological weapon should be considered a real possibility, although according to the available data, highly virulent viral suspensions spread very close to the target population would be necessary to infect a large number of persons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Schatzmayr. [Smallpox, an old foe].. https://doi.org/10.1590/s0102-311x2001000600024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Portable 24-analyte surface plasmon resonance instruments for rapid, versatile biodetection.

Field use of surface plasmon resonance (SPR) biosensors for environmental and defense applications such as detection and identification of biological warfare agents has been hampered by lack of rugged, portable, high-performance instrumentation. To meet this need, we have developed compact multi-analyte SPR instruments based on Texas Instruments' Spreeta sensing chips. The instruments weigh 3 kg and are built into clamshell enclosures measuring 28 cm x 22 cm x 13 cm. Functions are divided between an electronics unit in the base of the box and a fluidics assembly in the lid. Automated valves and pumps implement an injection loop flow system that allows sensors to be exposed to sample, rinsed, and treated with additional reagents (such as secondary antibodies) under computer control. Injected samples flow over the surfaces of eight sensor chips fastened into a temperature-controlled silicone flowcell. Each chip has 3 sensing regions, for a total detection of 24 areas that can be simultaneously monitored by SPR. Coating these areas with appropriate antibodies or other receptors allows a sample to be screened for up to 24 different substances simultaneously. The instruments report refractive index (RI) values every second, with a typical noise level of 1-3 x 10(-6) RI units. The design of the device is described, and performance is illustrated with detection of six distinct analytes ranging from small molecules to whole microbes during the course of a single experiment.

Biological Warfare↗

Laser-induced fluorescence-cued, laser-induced breakdown spectroscopy biological-agent detection.

Methods for accurately characterizing aerosols are required for detecting biological warfare agents. Currently, fluorescence-based biological agent sensors provide adequate detection sensitivity but suffer from high false-alarm rates. Combining single-particle fluorescence analysis with laser-induced breakdown spectroscopy (LIBS) provides additional discrimination and potentially reduces false-alarm rates. A transportable UV laser-induced fluorescence-cued LIBS test bed has been developed and used to evaluate the utility of LIBS for biological-agent detection. Analysis of these data indicates that LIBS adds discrimination capability to fluorescence-based biological-agent detectors. However, the data also show that LIBS signatures of biological agent simulants are affected by washing. This may limit the specificity of LIBS and narrow the scope of its applicability in biological-agent detection.

Biological Warfare↗