Rapid microfluidic mixing.

Abstract

A preformed T-microchannel imprinted in polycarbonate was postmodified with a pulsed UV excimer laser (KrF, 248 nm) to create a series of slanted wells at the junction. The presence of the wells leads to a high degree of lateral transport within the channel and rapid mixing of two confluent streams undergoing electroosmotic flow. Several mixer designs were fabricated and investigated. All designs were relatively successful at low flow rates (0.06 cm/s, > or = 75% mixing), but had varying degrees of success at high flow rates (0.81 cm/s, 45-80% mixing). For example, one design operating at high flow rates was able to split an incoming fluorescent stream into two streams of varying concentrations depending on the number of slanted wells present. The final mixer design was able to overcome stream splitting at high flow rates, and it was shown that the two incoming streams were 80% mixed within 443 microm of the T-junction for a flow rate of 0.81 cm/s. Without the presence of the mixer and at the same high flow rate, a channel length of 2.3 cm would be required to achieve the same extent of mixing when relying upon molecular diffusion entirely, while 6.9 cm would be required for 99% mixing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Timothy J Johnson, David Ross, Laurie E Locascio. 2002-01-01. Rapid microfluidic mixing.. https://doi.org/10.1021/ac010895d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Microchip PCR.

Miniaturization of genetic tests has become an important goal. This review surveys the current progress towards the miniaturization of tests based on the polymerase chain reaction (PCR). It examines the different types of PCR microchip designs, fabrication methods,and the components of a microchip PCR device. It also discusses the problems attributable to surface chemistry of microchip components (inhibition of PCR), and the static and dynamic surface passivation strategies developed for the solution of these difficulties

Equipment Design↗

Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.

OBJECTIVE: This study compared the recently introduced Microcuff endotracheal tube HVLP ICU featuring an ultrathin (7-microm) polyurethane cuff membrane with endotracheal tubes from different manufacturers regarding fluid leakage past the tube cuff. DESIGN: In vitro setup. MEASUREMENTS AND RESULTS: The following endotracheal tubes (ID 7.5 mm) were compared: Mallinckrodt HiLo, Microcuff HVLP ICU, Portex Profile Soft Seal, Rüsch Super Safety Clear, and Sheridan CF. A vertical PVC trachea model (ID 20 mm) was intubated, and cuffs were inflated to 10, 15, 20, 25, 30, and 60 cmH2O. Colored water (5 ml) was added to the top of the cuff. The amount of leaked fluid past the tube cuff within 5, 10, and 60 min was recorded. Experiments were performed four times using two examples of each tube brand. Fluid leakage past tube cuffs occurred in all conventional endotracheal tubes at cuff pressures from 10 to 60 cmH2O. In the Microcuff tube cuff pressure fluid leakage was observed within 10 min only at 10 cmH2O. Results with the Microcuff tube were significantly better than all other tube brands at cuff pressures of 10-30 cmH2O. CONCLUSIONS: Within the acceptable upper limit for tracheal cuff pressure (25-30 cmH2O) the Microcuff endotracheal tube was the only one of the tested tubes to prevent fluid leakage in our in vitro setup. In vivo studies are required to confirm these findings.

Equipment Design↗