PubMed Health⌕ Search

PubMed · 11798049

Probabilistic capture zone delineation based on an analytic solution.

Abstract

A major tool used in the design of wellhead protection areas is the delineation of a capture zone for a pumping well by use of a simple, steady-state analytic solution. This simple approach has been useful for many small municipalities because of the high costs associated with obtaining the hydrogeologic information needed for detailed numerical modeling. This analytic solution, however, is deterministic, and uncertainty in the mean value estimates of the hydraulic parameters used in this model can be a major source of error in predicting capture zones. To address this problem, a statistical theory was developed for including the uncertainty in the transmissivity and the magnitude and direction of the hydraulic head gradient in the analytic solution for both the ultimate and time-dependent capture zone for an arbitrary reliability level. To demonstrate the method and investigate the effect of varying magnitudes of uncertainty on time-dependent capture zones, the method is applied to three synthetic data sets based on data from the Borden Aquifer in Ontario, Canada. In general, the results show that uncertainty in the length of the time-dependent capture zone at a given reliability level is dependent on the uncertainty in the magnitude of the mean regional flow, which is equal to the transmissivity multiplied by the hydraulic head gradient; uncertainty in the maximum width of the capture zone is dependent primarily on the uncertainty in the mean direction of the regional flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elizabeth Jacobson, Roko Andricevic, Joseph Morrice. Probabilistic capture zone delineation based on an analytic solution.. https://doi.org/10.1111/j.1745-6584.2002.tb02494.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Eye rotation and vignetting in visual instruments.

The eye can rotate to accommodate the angular position of an object and the distance of the object from it. The rotation of the eye inside its socket to align its visual axis in the direction of an off-axis image may introduce full or partial vignetting when one is looking through a visual instrument with a real exit pupil. We analyze the effects of vignetting owing to rotation of the eye in visual instruments with real exit pupils.

Equipment Design↗

Large-aperture automatic focimeter for the measurement of optical power and other optical characteristics of ophthalmic lenses.

We propose an optical apparatus enabling the measurement of spherical power, cylindrical power, and optical center coordinates of ophthalmic lenses. The main advantage of this new focimeter is to provide a full bidimensional mapping of the characteristics of ophthalmic glasses. This is made possible thanks to the use of a large-area and high-resolution position-sensitive detector. We describe the measurement principle and present some typical mappings, particularly for progressive lenses. We then discuss the advantages in terms of speed and versatility of such a focimeter for the measurement of complex lens mappings.

Equipment Design↗

Measuring forces with the AFM: polymeric surfaces in liquids.

This review links together for the first time both the practicalities of force measurement and the work carried out to date on force detection between polymeric surfaces in liquids using the atomic force microscope (AFM). Also included is some of the recent work that has been carried out between surfactant surfaces and biologically coated surfaces with the AFM. The emphasis in this review is on the practical issues involved with force measurement between these types of surfaces, and the similarities and irregularities between the observed types of forces measured. Comparison is made between AFM and surface force apparatus (SFA) measurements, as there is a much longer history of work with the latter. Results indicate that forces between the surfaces reviewed here are a complicated mixture of steric-type repulsion, conformational behaviour on separation and long-range attraction, which is often ascribed to 'hydrophobic' forces. The origin of this latter force remains uncertain, despite its almost ubiquitous appearance in force measurements with these types of surfaces.

Equipment Design↗