Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach.

Abstract

OBJECTIVE: Many computer navigation systems have recently been developed for brain surgery, and the use of such systems in orthopedic surgery is increasing. Intraoperative registration of preoperative images is one of the most important steps in controlling the overall accuracy of computer navigation systems. Various parameters, such as CT-scan slice thickness, reconstruction pitch, intraoperative data sampling area, and data sampling volume, may affect the accuracy of registration. The purpose of this study was to evaluate the effect of the aforementioned parameters on the accuracy of registration for hip surgery performed through a posterolateral approach, and to find a clinically suitable trade-off between accuracy and surgical invasiveness. MATERIALS AND METHODS: One cadaveric pelvis and one cadaveric femur were used for this study. Four alumina ceramic balls with a diameter of 28 mm and within 1 micrometer of sphericity were attached to the pelvis, and three similar balls attached to the femur, to determine relative position. CT-scan images of the pelvis and femur were obtained with a helical scanner. Three sets of slice thickness and slice pitch were chosen for data acquisition, and two additional sets of reconstructed data were made. Bone contours were extracted by cutting out the surrounding substrate at a given CT number threshold, and surface models of the bone were made from the resultant data. The positions of the pelvis and femur were tracked by LED markers attached to the bone using an optical three-dimensional position sensor (OPTOTRAK). Registration of the computer models to the real objects was performed by measuring the position of a certain number of surface points on each object with an OPTOTRAK pen-probe. RESULTS AND CONCLUSION: Slice thickness and reconstruction pitch affected the accuracy of registration. As the sampling area was expanded from the periarticular area to the distant peripheral area, accuracy increased slightly. Accuracy did not increase when the whole area was used, but in fact decreased, especially in the femur. The positive effect of increasing the number of sampling points was saturated at 30 points when the surface of the periarticular area was sampled. The following trade-off between accuracy and invasiveness, in terms of various parameters of preoperative and intraoperative data, is proposed as clinically optimal: perform the CT scan with 3-mm slice thickness and 1-mm reconstruction pitch, and sample the periarticular area with 30 sampling points. With these parameters, the accuracy of registration was 1.2 mm and 0.9 degrees of bias with 0.7 mm and 0.3 degrees of RMS in the pelvis, and 1.4 mm and 0.6 degrees of bias with 1.3 mm and 0.3 degrees of RMS in the femur.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Sugano, T Sasama, Y Sato, Y Nakajima, T Nishii, K Yonenobu, S Tamura, T Ochi. 2001. Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach.. https://doi.org/10.1002/igs.10011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A population-based study of cancer incidence in solid organ transplants from donors at various risk of neoplasia.

A population-based cohort study of recipients of organs from donors with a recognized history or active cancer has been conducted by linking the Italian National Registry of Transplanted Patients and the National Registry of Donors with Neoplasia Risk. Between 2002 and 2004, 8,198 solid organ transplants have been performed in Italy, 108 of them with organs from 59 cadaveric donors with various risk of neoplasia. There were two reported cases of nonmelanoma skin cancer during the follow up of the transplanted patients, which lasted 27.6+/-11.3 months (234 patient-years). In our study, recipients of organs from donors with various degree of neoplasia risk are exposed to a low risk of cancer transmission.

Cadaver↗

[Primary stability of the capsule-labrum complex after reconstruction with the Mitek Bioknotless anchor system in human cadaver models].

BACKGROUND: This study examines the postoperative stability of the Mitek Bioknotless anchor system with biomechanical draw-out pulling in human cadaver shoulders. METHOD: With simulation of anterior shoulder dislocation a test group (n=10, Ø 45 years) was tested against a native group (n=8, Ø 47 years). All shoulders were dissected up to the passive stabilizers. In the test group an artificial Bankart lesion was created and repaired with three Mitek Bioknotless anchors. The humeri of both groups were fixed in 60 degrees glenohumeral abduction and 90 degrees external rotation and then dislocated in a ventral direction. For evaluation purposes the ultimate draw-out strength, mode of failure, translation of humeral head, capsular slope, and bone density in the test group were measured. RESULTS: In the test group the ultimate strength was a median of 937 N (min. 554 N, max. 1,294 N) with 28 bony anchor dislocations, 1 suture rupture, and 1 capsular rupture, and in the native group with 6 Bankart and 2 HAGL lesions it was 1,214 N (708 N, 1,471 N). The bone density showed a positive correlation to the draw-out strength regarding cortical density and total density. CONCLUSION: Regarding the high draw-out strength the Mitek Bioknotless anchor system provides enough stability for early functional treatment.

Cadaver↗