The sizer-dissector for aneurysm clip selection: technical note.

Abstract

OBJECTIVE: Appropriate clip selection frequently becomes a matter of trial and error because of inadequate dissection of the pathway for each clip blade. To facilitate selection of the proper clip size, a series of dissectors have been designed that mimic the exact caliber of each category of Sugita clips. METHODS: Three lines of sizer-dissectors reflecting the wire size of the most commonly used Sugita clips were developed by attaching a single aneurysm clip blade to a rounded microdissector handle. Each sizer-dissector is scaled in millimeters and is available in straight and angled configurations. Once dissection is presumed to be complete, the device is passed through the pathway of the intended aneurysm clip blades, and the clip with the appropriate caliber and length for permanent occlusion is selected. RESULTS: During dissection and clip ligation of 83 aneurysms, the sizer-dissector was used to select the blade length in 16 lesions and the blade caliber in 5 lesions. There were no complications associated with deployment of the device. CONCLUSION: By use of the sizer-dissector before attempting clip placement, clip selection is facilitated, safety is enhanced, and clip wastage is reduced.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Steven L Giannotta. 2002. The sizer-dissector for aneurysm clip selection: technical note.. https://doi.org/10.1097/00006123-200203000-00049

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗