PubMed Health⌕ Search

PubMed · 11843085

Shielding high energy accelerators.

Abstract

After introducing the subject or shielding high energy accelerators, point source, line-of-sight models, and in particular the Moyer Model, are discussed. Their use in the shielding of proton and electron accelerators is demonstrated and their limitations noted, especially in relation to shielding in the forward direction provided by large, flat walls. The limitations of reducing problems to those using a cylindrical geometry description are stressed. Finally the use of different estimators for predicting dose is discussed. It is suggested that dose calculated from track-length estimators will generally give the most satisfactory estimate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G R Stevenson. 2001. Shielding high energy accelerators.. https://doi.org/10.1093/oxfordjournals.rpd.a006624

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Technical note: reconstructing dose distributions from manually planned electron boosts in breast radiotherapy.

PURPOSE: In breast radiotherapy, delivery of manually-calculated electron boosts limits retrospective dose-response analyses as dose distribution is unavailable. This work evaluates the feasibility of reconstructing dose distributions from manually planned electron boosts in breast-conserving radiotherapy. METHODS: Only 72 out of 198 breast cancer patients had complete stored dose distributions from sequential electron boosts in the REQUITE study. Arbitrary data from 70/72 patients were used to develop and validate dose reconstruction method. Twenty patients were used to determine optimal parameters for Monte-Carlo-based (MC) electron dose reconstruction on RayStation (v.11B-R), considering CT-calibration curve, MC-history number, andcalculation grid resolution. Remaining 50 patients were used to quantify dose reconstruction accuracy. The similarity between reconstructed and stored dose was evaluated using 3D-gamma index and dosimetric parameters extracted from breast and tumour bed contours. Dose difference location was evaluated using dose-location histogram. RESULTS: Calculation grid resolution significantly impacted electron dose distribution (p&#xa0;<&#xa0;0.01), where the finest grid (0.15&#xa0;cm) showed highest similarity to stored doses. CT-calibration curve and MC-history number had a negligible influence on dose reconstruction. Dosimetric difference between reconstructed and stored doses was&#xa0;<&#xa0;1&#xa0;Gy for breast and tumour bed. Reconstructed dose was achieved&#xa0;>&#xa0;90% gamma passing rate in the validation set. However, around 2.5&#xa0;Gy dose differences were observed at the skin and tissue interface regions. CONCLUSIONS: Retrospective electron boost dose reconstruction is feasible with acceptable accuracy, and could increase data completeness in large cohort studies. Caution is advised when assessing dose near tissue interface and further validation is needed outside the REQUITE dataset.

Electrons↗

Electron-conformational study for the structure-hallucinogenic activity relationships of phenylalkylamines.

The structure-hallucinogenic activity relationships of a series of phenylethylamine and phenylisopropylamine derivatives have been investigated in the frameworks of electron-conformational method. The calculated geometry and electronic structure parameters accompanying to each atom and bond of each molecule in view were arranged as a matrix called electron-conformational matrix of contiguity (ECMC). The features that are responsible for strong and weak activity demonstrations have been found as submatrices of ECMCs belonging to some template compounds. Two electron-conformational features present in nonhallucinogenic compounds have been revealed. A quantitative model has been improved for predicting hallucinogenic activity numerically. A test series was used to verify the results obtained.

Electrons↗

Degradation of PCBs in a marine sediment treated with ionizing and UV radiation.

Radiolytic (electron beam) and photolytic (ultraviolet, UV) dechlorination of polychlorinated biphenyls (PCBs) in a marine sediment are described. Samples of a PCB-laden marine sediment, Standard Reference Material (SRM) 1944, NewYork/New Jersey Waterway Sediment, have been mixed with aqueous alcohol solutions and irradiated with an electron beam or photolyzed. Additives, such as alcohol, enhance the radiolytic yield and PCB dechlorination. In the electron beam irradiated samples, the concentrations of 29 PCB congeners decrease with irradiation dose. At the highest dose (500 kGy), the total concentration of PCBs is decreased by 83%. Photolysis leads to little dechlorination, but photolysis with added triethylamine leads to dechlorination (about 60%). It is likely that photolysis under optimal conditions (other additives, exposure time) may be as effective as electron beam radiolysis for the dechlorination of PCBs in sediment.

Electrons↗