PubMed Health⌕ Search

PubMed · 11856565

MRI volume measurements of hypointense objects. A phantom study using stereological methods.

Abstract

Volume estimates made from thick slabs overestimate the volume of a positive contrast particle in a translucent matrix and underestimate its volume if the particle has negative contrast and the matrix is opaque. For T2-weighted MRI high signal objects the bias can be corrected according to simple geometric models. For negative contrast or hypointense objects the magnitude of the bias is unknown and no corrections have yet been put forward. We wanted to determine the bias of MRI measurements of hypointense objects of known diameter surrounded by a positive contrast solution. One, 3 and 5 mm slices with three different contrast concentrations were obtained according to a stereological MRI protocol. Results were compared with the true object size to estimate the bias. A simple correction for the bias could not be developed due to interslice cross-talk. Cross-talk makes an object appear in more MRI slices than corresponding to its physical size and larger than the true diameter. For phantom measurements an empirical correction could be developed, but for measurements of non-ideal objects such as brain structures the validity of the correction would be unpredictable. Besides avoiding or reducing cross-talk, the best way to deal with this bias is to measure the object's maximal contrast from edge to edge, a solution which is not perfect.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paula Gadeberg, Hans J G Gundersen, Finn Taagehøj, Johannes Jakobsen. 2002-03-15. MRI volume measurements of hypointense objects. A phantom study using stereological methods.. https://doi.org/10.1016/s0165-0270(01)00513-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultra-high-field 7T MRI reveals neural abnormalities of attention networks in relation to cognitive impairment in hypertension.

Hypertension is a significant risk factor for cognitive impairment (CI), yet the corresponding neural network abnormalities remain underexplored. In this study, we examined the associations among global and domain-specific cognitive dysfunction, neuroimaging measures, and blood pressure in a subgroup of hypertensive patients with CI (N = 41) from a randomized controlled trial who underwent ultra-high-field 7 T MRI. Structural atrophy related to CI was localized to regions overlapping the attention networks. Both whole-brain and within-network dysfunction of the attention networks were associated with worse global cognitive performance. Notably, hyperconnectivity within key attention network hubs, including the right anterior insula and posterior intraparietal sulcus, was associated with declined processing speed in hypertensive patients, mediating the association between pulse pressure and processing speed. These findings provide new insights into the neural pathophysiology of hypertension-related CI and suggest potential network-based targets for intervention.

Magnetic Resonance Imaging↗

Structure-specific magnetic field inhomogeneities and its effect on the correlation time.

We describe the relationship between the correlation time and microscopic spatial inhomogeneities in the static magnetic field. The theory takes into account diffusion of nuclear spins in the inhomogeneous field created by magnetized objects. A simple general expression for the correlation time is obtained. It is shown that the correlation time is dependent on a characteristic length, the diffusion coefficient of surrounding medium, the permeability of the surface and the volume fraction of the magnetized objects. For specific geometries (spheres and cylinders), exact analytical expressions for the correlation time are given. The theory can be applied to contrast agents (magnetically labeled cells), capillary network, BOLD effect and so forth.

Magnetic Resonance Imaging↗

[Experimental study of coil selection considered from subject size].

We examined the index of coil selection in consideration of subject size to measure signal-to-noise ratio (SNR) and uniformity in a phantom experiment. The QD-Head, 8-channel-Head, and 8-channel-Head-Neck coil were used for head examination, QD-Body, 4-channel-TORSO, and 8-channel-Body coil were used for body examination. In the examination of the head, measurements were performed at various positions in a coil. The SNR measured by the QD-Head coil showed the highest values for 9 cm or 12 cm diameters of the phantom, and 10 cm to 15 cm distance from the coil entrance. The QD-Head coil also showed adequate uniformity at most sizes of phantoms. In the body examination, both multi-channel coils showed an SNR higher than the QD-Body coil for all sizes, but they were inferior to the QD-Body coil in uniformity. The 4-channel-TORSO coil showed an SNR higher than the 8-channel-Body coil when a phantom with a diameter of 21 cm or less was used. Since sensitivity distributions differ according to various cases, the 8-channel coil does not necessarily always show a high SNR. It is necessary to perform coil selection according to the subject's size and purpose.

Magnetic Resonance Imaging↗