Abstract

OBJECTIVE: The present study investigated the acceptability and the effect of Adaptive dynamic range optimization (ADRO) on speech perception for cochlear implant subjects. ADRO is a preprocessing scheme that continuously adjusts the gain in each frequency band to optimize the signal in the output dynamic range. DESIGN: Speech processor programs were created with and without ADRO processing. Nine subjects were tested in the laboratory and encouraged to use both programs in everyday listening situations. Take-home experience was assessed with preference questionnaires. Speech perception performance was compared for the standard and ADRO programs using City University of New York (CUNY) sentences, consonant-nucleus-consonant (CNC) words, and closed set spondees presented in quiet. A range of presentation levels were used; from 70 to 40 dB sound pressure level (unweighted RMS). CUNY sentences were also presented in multi-talker babble with +15 dB and +10 dB signal to noise ratios. RESULTS: There was a significant improvement in speech perception scores with the ADRO programs compared with the standard. At 50 dB, the mean open set sentence scores in quiet improved by 16% (p < 0.001). There was an improvement in mean word score for CNC words presented at 60 dB of 9.5% (p < 0.001) and a 20% improvement in mean score for spondees presented at 40 dB. There was no significant difference in sentence scores between the ADRO and the standard program for sentences presented in either noise condition. ADRO was the preferred program in 59% of listening situations, with five out of nine subjects indicating a strong overall preference and three subjects indicating a slight preference for ADRO. CONCLUSIONS: Continual adjustment of channel gains using ADRO provided improved sound quality and improved speech perception performance. Therefore, ADRO is a viable alternative to fixed channel gain and offers a means for cochlear implantees to gain more benefit from their devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chris J James, Peter J Blamey, Lois Martin, Brett Swanson, Yvette Just, David Macfarlane. 2002. Adaptive dynamic range optimization for cochlear implants: a preliminary study.. https://doi.org/10.1097/00003446-200202001-00006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multi-channel evoked response detection using only phase information.

The phase consistency of contiguous segments of the electroencephalogram (EEG) has been used in the detection of evoked responses to rhythmic stimulation. One of such techniques is the component synchrony measure (CSM), which is often used since the threshold for the detection task is easily obtained based on the estimates of asymptotic sample distribution. In this work we investigated the appropriateness of such thresholds for practical number of segments (M). The performance of CSM was next evaluated by Monte Carlo simulations with different signal-to-noise ratios (SNR) and values of M, and the results, compared with those for the magnitude-squared coherence. A way of improving the detection with CSM was also proposed, by suggesting the estimation taking into account the mean phase angle of a set of N signals. This multivariate detector was evaluated in simulations and an illustration of the technique was also given with the EEG of 14 subjects during photic stimulation. In simulated signals with equal SNR, the detection rate with this multivariate measure increased with N. The application to EEG data lead to similar results in 70% of the subjects, which suggests that improvements might be expected when more signals are available to detect evoked responses in EEG.

Acoustic Stimulation↗

Evidence for the different additivity of the temporal and frontal generators of mismatch negativity: a human auditory event-related potential study.

The auditory sensory-memory mechanisms in the human brain were investigated using the mismatch negativity (MMN) component of the event-related potential. MMNs were recorded to stimuli deviating from the repetitive standard stimuli simultaneously either in one or two features (frequency, intensity). If the processing of these two features is independent of each other, the MMN to the double deviant should equal the sum of the MMNs elicited by the corresponding single deviants. The double-deviant MMNs were found to be additive at the electrode sites below the Sylvian fissure but not at the frontal scalp areas. The results suggest that the temporal subcomponent of MMN is additive whereas the frontal is non-additive. The pattern of results was similar in ignore and attend conditions, suggesting that the components were not attentionally modulated.

Acoustic Stimulation↗

A temporal window for the central inhibition of stuttering via exogenous speech signals in adults.

We explored a possible temporal window for central stuttering inhibition via exogenously presented speech signals. Thirteen adults who stutter were asked to read while listening to a continuous vowel /a/, or a repeating 1 s vowel /a/ followed by 1, 3 and 5 s silences. In all conditions, stuttering was significantly reduced. However, the continuous and 1 s repeating conditions showed the greatest reduction in stuttering relative to all other conditions. Furthermore, these conditions did not differ significantly from each other, suggesting a temporal window of at least 1 s for stuttering inhibition induced by a 1 s stimulus. We propose that exogenous speech signals provide an additional speech source that engages mirror neurons for 'on-line' stuttering inhibition during continous speech. Employing dual speech sources results in 'on-line' stuttering inhibition and continuous speech flow. In contrast, endogenous (single source) inhibitory techniques require speech flow to be interrupted and go 'off-line' to derive the mirror neuronal.

Acoustic Stimulation↗