PubMed Health⌕ Search

PubMed · 11892223

The modified split bridge method to prevent electrode slip-out.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Kawano, H Chiba, K Ueda, N Nishiyama, M Suzuki. 2000. The modified split bridge method to prevent electrode slip-out.. https://doi.org/10.1159/000059156

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recurrent extrusion of cochlear implant at an interval of 5 years.

OBJECTIVE: To describe two different types of device extrusion occurring in the same patient 1 and 6 years after cochlear implantation and to discuss the relation between the two extrusions and problems of cochlear implantation in patients with chronic suppurative otitis media. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENT AND INTERVENTIONS: The patient was a 52-year-old man with profound hearing loss in the right ear caused by chronic otitis media and deafness in the left ear caused by removal of an acoustic neuroma. Surgery for cleaning the tympanic cavity and reconstruction of the bony canal after previous radical mastoidectomy was performed in the right ear first. One year later, cochlear implantation was performed in this ear. RESULTS: One year after implantation, the anterior edge of the internal device of cochlear implant was exposed along the skin incision. This site was stable after corrective surgery. Five years after this operation, however, the posterior edge of the internal device extruded, accompanied by infection around the device. CONCLUSION: The two extrusions occurred with a long interval in between and at two different sites. The first extrusion occurred along the skin incision, and the second extrusion occurred away from the skin incision with infection around the device. The authors assumed that the first and the second extrusion occurred independently; the first extrusion was caused by insufficient blood supply resulting from scar formation from repeated mastoid operations and by pressure on the skin from the internal and external devices, and the second extrusion was caused by proliferated tissue pushing the device upward and against the skin as a result of chronic middle ear infection. The clinical course indicates that sufficiently long follow-up periods are needed to determine the usefulness of the prevention techniques for cochlear implantation in patients with chronic suppurative otitis media.

Cochlear Implantation↗

Nondestructive three-dimensional analysis of electrode to modiolus proximity.

PURPOSE: To propose a nondestructive method for three-dimensional analysis of inner ear morphology after cochlear implantation for isolated petrous bones. MATERIALS AND METHODS: After implantation of cochlear implant electrode arrays, fresh temporal bones were investigated on a new C-arm-based radiographic device permitting the generation of cross-sectional images and of three-dimensional models from multiple two-dimensional radiographic images taken under different projections (cone-beam computed tomography). Cross-sectional images and multiplanar reformations with a slice thickness of 0.15 mm were acquired. The relationship of the electrode to the modiolus was analyzed (distance between electrode and the modiolus; position of the electrode inside the tympanic or vestibular scale). Histologic preparation was used as a gold standard. RESULTS: In all cases, cone-beam computed tomography gave similar information concerning the position of the electrode compared with histologic analysis (tympanic scale versus vestibular scale, proximity versus distance to the modiolus). Perforation of the electrode from the tympanic to the vestibular scale could be assessed three-dimensionally in the cross-sectional images. In contrast to histology, cross-sectional imaging based on radiography is performed in less than 10 minutes and needs no preparation of the object. Because it is nondestructive, it can be repeated and used as a control after position-correcting maneuvers. CONCLUSION: Cross-sectional imaging based on radiography is a valuable tool for the analysis of the electrode-modiolus relationship after cochlear implantation in isolated temporal bones, which may confirm histologic analysis.

Cochlear Implantation↗