PubMed Health⌕ Search

PubMed · 11908521

Life support system using water electrolysis.

Abstract

The purpose of the integrated physiologico-hygienic and biotechnological laboratory experiment was to evaluate the effect of life support subsytems placed inside a sealed cabin on the cabin environment and, consequently, on the human performance and activity, and also to assess the operability of subsystems by the crewmen and disclose any resulting difficulties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B A Adamovich, B A Gavrilov, B G Grishaenkov, Y G Nefedov. Life support system using water electrolysis.. https://doi.org/10.1016/0094-5765(74)90079-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Outbreak of invasive Aspergillus infection in surgical patients, associated with a contaminated air-handling system.

An outbreak of Aspergillus infection at a tertiary care hospital was identified among inpatients who had amputation wounds, peritonitis, allograft nephritis, or mediastinitis. During a 2-year period, 6 patients were identified, all of whom had Aspergillus species recovered from samples from normally sterile sites. All cases clustered in the operating theater during a single 12-day period. To assess operating theater air quality, particle counts were measured as surrogate markers for Aspergillus conidia. A substantial increase in the proportion of airborne particles > or =3 microm in size (range, 3-fold to 1000-fold) was observed in many operating rooms. A confined space video camera identified moisture and contamination of insulating material in ductwork and variable airflow volume units downstream of final filters. No additional invasive Aspergillus wound infections were identified after the operating theater air-handling systems were remediated, suggesting that this unusual outbreak was due to the deterioration of insulating material in variable airflow volume units.

Air Conditioning↗

Molecular modeling of polymer composite-analyte interactions in electronic nose sensors.

We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL electronic nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereoisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings with no hydrogens. The Dreiding 2.21 force field is used for the polymer, solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4-vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic and organic compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites.

Air Conditioning↗

New problems to be solved for establishing closed life support system.

New test bed facilities such as Bioplex and CEEF have been constructed to test the new advanced technologies for solving the various problems as follows, (1) how to develop air content stabilization technologies with gas balance between the generation and the absorption by living organisms, (2) how to solve the mismatching between the assimilation rate of autotrophic organisms and the respiration rate of heterotrophic organisms, (3) how to balance the speed of the waste decomposition with the absorption speed of nutrient components in the sequential plant cultivation, (4) how to develop new nutrient adjusting subsystems for each plant species, (5) how to compensate the denitrification during the waste decomposition and anaerobic microbes in the nutrient solution.

Air Conditioning↗