PubMed Health⌕ Search

PubMed · 11914420

Midbrain deafness with normal brainstem auditory evoked potentials.

Abstract

The authors report two cases of patients with word deafness. The word deafness occurred after a head injury for the first patient and after an arterio venous malformation embolization for the second patient. MRI demonstrated bilateral lesions of the inferior colliculi but brainstem auditory-evoked potentials (BAEP) were within normal limits. These cases demonstrated that lesions involving the two inferior colliculi induced pure word deafness but do not affect BAEP.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Vitte, F Tankéré, I Bernat, A Zouaoui, G Lamas, J Soudant. 2002-03-26. Midbrain deafness with normal brainstem auditory evoked potentials.. https://doi.org/10.1212/wnl.58.6.970

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a posterior cerebral artery aneurysm subsequent to occlusion of the contralateral internal carotid artery for giant cavernous aneurysm.

We report a case of a patient who developed a left posterior cerebral artery aneurysm 5 years after balloon occlusion of the right internal carotid artery for a giant cavernous aneurysm. The location of the new aneurysm was outside of the primary collateral pathways to the contralateral, proximally occluded, anterior circulation, illustrating the complexity of hemodynamic factors contributing to the development of intracranial saccular aneurysms. The appearance of an aneurysm in this setting supports the hypothesis that degenerative factors and hemodynamic stresses are important in the etiology of intracranial aneurysms.

Balloon Occlusion↗

Controlled tamponade of severe presacral venous hemorrhage: use of a breast implant sizer.

Hemorrhage from the presacral venous plexus is a potentially life-threatening complication of pelvic operations. The morbidity and mortality that stems from severe hemorrhage has led to the development of various hemostatic techniques. Although suture ligature, packing, and placement of tacks can be very effective, they can often be unsuccessful. When these conventional hemostatic techniques fail, alternative approaches are required. We describe the successful use of an expandable breast implant sizer and outline the practical, theoretical, and financial advantages of applying this technique when more conservative approaches have failed.

Balloon Occlusion↗