PubMed Health⌕ Search

PubMed · 11948262

Contamination problem with sentinel node localization procedure: a case study.

Abstract

Lymphoscintigraphy for sentinel node (SN) localization was performed on a 60-y-old man with a melanoma on his back. Skin contamination occurred as a result of the radiopharmaceutical dose administration. Skin contamination could result in a misinterpretation of the SN location. Careful observation of the procedure avoided a misinterpretation with this study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Warner, Steven Hovey, Elpida S Crawford. 2002. Contamination problem with sentinel node localization procedure: a case study.. https://pubmed.ncbi.nlm.nih.gov/11948262/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Enhanced bio-manufacturing through advanced multivariate statistical technologies.

The paper describes the interrogation of data, from a reaction vessel producing an active pharmaceutical ingredient (API), using advanced multivariate statistical techniques. Due to the limited number of batches available, data augmentation was used to increase the number of batches thereby enabling the extraction of more subtle process behaviour from the data. A second methodology investigated was that of multi-group modelling. This allowed between cluster variability to be removed, thus allowing attention to focus on within process variability. The paper describes how the different approaches enabled the realisation of a better understanding of the factors causing the onset of an impurity formation to be obtained as well demonstrating the power of multivariate statistical data analysis techniques to provide an enhanced understanding of the process.

Artifacts↗

Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account.

UNLABELLED: The aim of this study was to establish normal values for overnight oxygen saturation (SpO2) in healthy term infants using an oximeter which takes into account motion artifacts and to compare these to normal values collected with a previous generation oximeter not correcting for motion artifacts. We recorded overnight SpO2 in 26 term, healthy infants (median age 136 days, range 6-364 days) in the home environment using the Nellcor Symphony N 3000 pulse oximeter with an averaging time of 3 s. A sample rate of 5 s was chosen. Motion artifacts were excluded from the analysis. Data were compared with those from a previous study, using the same inclusion and exclusion criteria with the Oxford Medilog. Median (quartiles) SpO2 was 98% (97%-99%). Median percentage of study time below SpO2 94% was 0.2% (0.1%-0.7%); median percentage of study time below SpO2 90% was 0.0% (0.0%-0.01%). Median SpO2with the Oxford oximeter was 97% (96%-98%); percentage of study time below SpO2 94% was 8% (2%-14%); percentage of study time below SpO2 90% was 2% (0%-4%). These data were compared with the Nellcor Symphony data: differences in median SpO2 were significant ( P<0.05); differences in percentage of time below SpO2 94% and 90% were also statistically significant ( P<0.001). CONCLUSION: we established normal values of oxygen saturation in healthy term infants using the Nellcor Symphony 3000 pulse oximeter. Care should be taken in interpreting values obtained with different types of pulse oximeters.

Artifacts↗