PubMed Health⌕ Search

PubMed · 11954712

New criteria for estimating baroreflex sensitivity using the transfer function method.

Abstract

Computer simulations were carried out to appraise three new criteria for the estimation of baroreflex sensitivity (BRS) using the transfer function method. The major goal was to identify a computation procedure able to overcome the intrinsic limitations of the classical coherence criterion. Four representative shapes of the gain function and three different average gains (2, 5 and 8 ms(mmHg)(-1) in the low-frequency (LF) band (0.04-0.15Hz) were considered. The signal-to-noise ratio was made to vary so that the peak coherence in the LF band changed from 0.15 to 0.9. All simulation parameters were derived from previous observations in healthy subjects and heart disease patients. The error of the estimated gain function was obtained from its confidence interval. BRS was computed as average gain in the LF band: (a) including in the average only those points having error < or = threshold (criterion 1, C1); (b) calculating the mean error in the band and accepting BRS measurements only when this error was < or = threshold (criterion 2, C2); (c) including in the average all points, regardless of the error (criterion 3, C3). The three criteria were compared in terms of measurability (percentage of measured BRS) and accuracy (bias and SD of BRS). Using C1 and C2, measurability dropped to 10% when the peak coherence in the LF band decreased, respectively, to 0.18-0.41 and to 0.26-0.53, depending on the shape and strength of the gain. In this condition (lower bound of measurability), worst bias and SD (average gain: 8 ms(mmHg)(-1)) were, respectively, 0.8 ms(mmHg)(-1) and 3.3ms(mmHg)(-1) (C1), and 0.1 ms(mmHg)(-1) and 1.0 ms(mmHg)(-1) (C2). C3, by definition, always ensured 100% measurability and showed bias and SD comparable with, or even lower than, C1 and C2, within the common range of measurable BRS. In the extreme condition of 0.15 coherence, bias and SD were, respectively, 1.7 ms(mmHg)(-1) and 2.3ms(mmHg)(-1) (average gain: 8ms(mmHg)(-1)). Hence, error checking (C1 and C2) dramatically reduced measurability and did not improve accuracy of BRS measurements compared with performing no error check (C3). In conditions of low signal-to-noise ratio and/or impaired baroreflex gain, leading to markedly reduced coherence, the simple average of the gain function in the LF band allows BRS to be estimated with accuracy adequate for clinical purposes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G D Pinna, R Maestri. 2002. New criteria for estimating baroreflex sensitivity using the transfer function method.. https://doi.org/10.1007/bf02347699

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of heat stress on baroreflex function in humans.

INTRODUCTION: Heat stress significantly reduces orthostatic tolerance in humans. The mechanism(s) causing this response remain unknown. The purpose of this review article is to present data pertaining to the hypothesis that reduced orthostatic tolerance in heat stressed individuals is a result of heat stress induced alterations in baroflex function. METHODS: In both normothermic and heat stressed conditions baroreflex responsiveness was assessed via pharmacological and non-pharmacological methods. In addition, the effects of heat stress on post-synaptic vasoconstrictor responsiveness were assessed. RESULTS: Generally, whole body heating did not alter baroreflex sensitivity defined as the gain of the linear portion of the baroreflex curve around the operating point. However, whole body heating shifted the baroreflex curve to the prevailing (i.e. elevated) heart rate and muscle sympathetic nerve activity. Finally, the heat stress impaired vasoconstrictor responses to exogenous administration of adrenergic agonists. CONCLUSION: Current data do not support the hypothesis that reduced orthostatic tolerance associated with heat stress in humans is due to impaired baroreflex responsiveness. This phenomenon may be partially due to the effects of heat stress on reducing vasoconstrictor responsiveness.

Baroreflex↗

Sympathetic nerve activity in obstructive sleep apnoea.

The mechanisms underlying the link between obstructive sleep apnoea (OSA) and cardiovascular disease are not completely established. However, there is increasing evidence that autonomic mechanisms are implicated. A number of studies have consistently shown that patients with OSA have high levels of sympathetic nerve traffic. During sleep, repetitive episodes of hypoxia, hypercapnia and obstructive apnoea act through chemoreceptor reflexes and other mechanisms to increase sympathetic drive. Remarkably, the high sympathetic drive is present even during daytime wakefulness when subjects are breathing normally and no evidence of hypoxia or chemoreflex activation is apparent. Several neural and humoral mechanisms may contribute to maintenance of higher sympathetic activity and blood pressure. These mechanisms include chemoreflex and baroreflex dysfunction, altered cardiovascular variability, vasoconstrictor effects of nocturnal endothelin release and endothelial dysfunction. Long-term continuous positive airway pressure treatment decreases muscle sympathetic nerve activity in OSA patients. The vast majority of OSA patients remain undiagnosed. Unrecognized OSA may contribute, in part, to the metabolic and cardiovascular derangements that are thought to be linked to obesity, and to the association between obesity and cardiovascular risk. Furthermore, acting through sympathetic neural mechanisms, OSA may contribute to or augment elevated levels of blood pressure in a large proportion of the hypertensive patient population.

Baroreflex↗