Abstract

A catheter complications survey study, carried out over a 2-year period in three Bristol health districts, recorded 506 emergency referrals during a 6-month period (Kohler-Ockmore and Feneley, 1996). A further detailed study on 54 of the patients showed that 48% experienced catheter blockage and 37% reported urine bypassing. Urinary catheterization can cause many health problems; bacteriuria is inevitable in long-term catheterized patients (Cravens and Zweig, 2000). This article identifies some of the common problems that can occur with long-term catheters, makes recommendations and applies an evidence-based approach to catheter care. In order to identify and treat the associated problems, it is necessary to understand the anatomy and functions of the bladder. The article addresses this before examining the problems, which include: catheter blockage; bypassing of urine; catheter rejection and balloon non-deflation; and latex allergy. The psychological and social aspects, although not covered in this article, are also important and should always be considered along with all other aspects of care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Rew, S Woodward. Troubleshooting common problems associated with long-term catheters.. https://doi.org/10.12968/bjon.2001.10.12.5302

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The role of surgery in the management of septic shock--extra-abdominal causes of sepsis.

Septic shock is a severe inflammatory response to one or more pathogenic micro-organisms. When a person's immune response is excessively intense, a cascade of phenomena may be activated that ultimately is harmful. Appropriate management of septic shock may include surgical intervention to remove or neutralize the septic focus in an effort to treat the inflammatory response cascade. This is the first of two articles presenting current information on the role of surgery in the management of a patient with septic shock. This article describes extra-abdominal sources of sepsis.

Catheters, Indwelling↗

Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

Catheters, Indwelling↗