Correcting low-frequency phase distortion in electroglottograph waveforms.

Abstract

Dynamic high-pass filtering with a -3 dB frequency that is a factor of ten or more below the voice fundamental frequency has a negligible effect on the amplitudes of the Fourier components of an EGG waveform. However, such a filter can significantly distort the waveform due to distortion in the phase or time alignment of these Fourier components. Such high-pass filtering can be introduced purposefully to stabilize the waveform by attenuating low-frequency noise, or may be an undesired effect of using an amplification or data acquisition system designed for acoustic signals. For a given voice fundamental frequency, the amount of distortion depends greatly on the order or attenuation characteristics of the filter and on the type of EGG waveform. Both a high-order filter and a breathy voice tend to increase the amount of distortion. If the characteristics of the high-pass filter are known, there are a number of digital filter techniques that can be used to reduce the phase distortion. However, it is shown that a relatively simple analogue network can also be used to obtain a correction that suffices for most applications. If the precise characteristics of the filter are not known, the response to a square wave can be used to adjust the compensator parameters for an optimal correction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin Rothenberg. 2002. Correcting low-frequency phase distortion in electroglottograph waveforms.. https://doi.org/10.1016/s0892-1997(02)00069-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gastric myoelectrical activity in neonates of different gestational ages by means of electrogastrography.

PURPOSE: to describe the patterns of the gastric myoelectrical activity, pre-and postprandially, in clinically stable neonates of different gestational ages, during their first two weeks of life by means of Electrogastrography. PATIENTS AND METHODS: Electrogastrography was recorded in forty-five clinically stable neonates of different gestational ages (group I: 15 neonates of > 37 weeks, group II: 15 premature neonates of 32-37 weeks; Group III: 15 premature neonates of 28-31 weeks) receiving intermittent enteral feedings during their first two weeks of life. Electrogastrography recordings were performed for 1 hour pre-and postprandially. The Electrogastrography signal was recorded using the portable MicroDigitrapper Electrogastrography recording device and after motion artifacts were deleted, the remaining Electrogastrography data were submitted to quantitative analysis based on the "Running Spectrum Analysis". RESULTS: The percentages of normogastria, pre-and postprandially were greater than the percentages of gastric dysrythmias in all three studied groups. Furthermore, all neonates had the mean values of the Electrogastrography dominant frequency predominantly within the normogastria range, in both periods analyzed. There were no significant differences in the relative change of the Electrogastrography dominant power among the groups. CONCLUSION: This study demonstrates that the Electrogastrography patterns are similar between premature and full term neonates during the pre-and postprandial periods. The results of this study also indicate that the gastric myoelectrical activity in premature and full term neonates is immature, as compared to that described for older neonates, children and adults.

Electromyography↗

Mechanomyography versus electromyography, in monitoring the muscular fatigue.

BACKGROUND: The use of the mechanomyogram (MMG) which detects muscular vibrations generated by fused individual fiber twitches has been refined. The study addresses a comparison of the MMG and surface electromyogram (SEMG) in monitoring muscle fatigue. METHODS: The SEMG and MMG were recorded simultaneously from the same territory of motor units in two muscles (Biceps, Brachioradialis) of the human (n = 18), during sustained contraction at 25 % MVC (maximal voluntary contraction). RESULTS: The RMS (root mean square) of the SEMG and MMG increased with advancing fatigue; MF (median frequency) of the PSD (power density spectra) progressively decreased from the onset of the contraction. These findings (both muscles, all subjects), demonstrate both through the SEMG and MMG a central component of the fatigue. The MF regression slopes of MMG were closer to each other between men and women (Biceps 1.55%; Brachialis 13.2%) than were the SEMG MF slopes (Biceps 25.32%; Brachialis 17.72%), which shows a smaller inter-sex variability for the MMG vs. SEMG. CONCLUSION: The study presents another quantitative comparison (MF, RMS) of MMG and SEMG, showing that MMG signal can be used for indication of the degree of muscle activation and for monitoring the muscle fatigue when the application of SEMG is not feasible (chronical implants, adverse environments contaminated by electrical noise).

Electromyography↗