Ball stud inspection system using machine vision.

Abstract

In this paper, a vision-based inspection system that measures the dimensions of a ball stud is designed and implemented. The system acquires silhouetted images by backlighting and extracts the outlines of the nearly dichotomized images in subpixel accuracy. The sets of boundary data are modeled with reasonable geometric primitives and the parameters of the models are estimated in a manner that minimizes error. Jig-fixtures and servo systems for the inspection are also contrived. The system rotates an inspected object to recognize the objects in space not on a plane. The system moves the object vertically so that it may take several pictures of different parts of the object, resulting in improvement of measuring resolution. The performance of the system is evaluated by measurement of the dimensions of a standard ball, a standard cylinder, and a ball stud.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dongik Shin, Changsoo Han, Young Shik Moon. 2002. Ball stud inspection system using machine vision.. https://doi.org/10.1016/s0019-0578(07)60197-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mineral content in legumes and nuts: contribution to the Spanish dietary intake.

We evaluated the levels of essential elements as Cu, Cr, Fe and Zn, and toxic elements as Al, Ni, Pb and Cd in a total of 40 samples of different legumes and 56 samples of different nuts, that are widely consumed in Spain. These elements were determined in the samples mineralized with HNO(3) and V(2)O(5), using electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. Reliability of the procedure was checked by analysis of a certified reference material. No matrix effects were observed and aqueous standard solutions were used for calibration. In legumes, the levels ranged from 1.5-5.0 microg Cu/g, 0.05-0.60 microg Cr/g, 18.8-82.4 microg Fe/g, 32.6-70.2 microg Zn/g, 2.7-45.8 microg Al/g, 0.02-0.35 microg Ni/g, 0.32-0.70 microg Pb/g and not detectable-0.018 microg Cd/g. In nuts, the levels ranged from 4.0-25.6 microg Cu/g, 0.25-1.05 microg Cr/g, 7.3-75.6 microg Fe/g, 25.6-69.0 microg Zn/g, 1.2-20.1 microg Al/g, 0.10-0.64 microg Ni/g, 0.14-0.39 microg Pb/g, and not detectable-0.018 microg Cd/g. A direct statistical correlation between Cu-Cr, Zn-Al and Cr-Ni (P<0.05), and Al-Pb (P<0.001), has been found. The growing popularity of these products in recent years on the basis of its nutritional properties and beneficial effects, requires additional data and a periodical control. In addition, the present findings are of potential use to food composition tables.

Calibration↗

High-performance liquid chromatographic method for determination of 2-difluoromethyl-DL-ornithine in plasma and cerebrospinal fluid.

A simple, sensitive, selective and reproducible method based on anion-exchange liquid chromatography with post-column derivatisation was developed for the determination of eflornithine (2-difluoromethyl-DL-ornithine; DFMO) in human plasma and cerebrospinal fluid. The 1-alkylthio-2-alkyl-isoindoles fluorescent derivative of the drug was separated from the internal standard (MDL 77246A) on an anion-exchange column (PRP-X300, 250x2.1 mm, 7-microm particle size: Hamilton, USA), with retention times of 6.9 and 10.7 min, respectively. Fluorescence detection was set at 430/340 nm (emission/excitation wavelength). The elution solvent consisted of a solution of 30 mM potassium dihydrogen phosphate buffer (pH 2.2) and acetonitrile (50:50, v/v), running through the column at a flow-rate of 0.3 ml/min. The chromatographic analysis was operated at 37 degrees C. Sample preparation for either plasma or CSF (100 microl) was done by single-step protein precipitation with 20% trichloroacetic acid after incubation at 4 degrees C for 1 h. Calibration curves for plasma (100, 200, 400, 600, 800 and 1200 nmol/100 microl, and 10, 20, 40, 80, 120 and 160 nmol/100 microl for the high and low concentration range curves, respectively) and CSF (1, 2, 4, 8, 16, 32 nmol/100 microl) were all linear with correlation coefficients better than 0.999. The precision of the method based on within-day repeatability and reproducibility (day-to-day variation) at high concentration range was below 15%, whereas at low concentration range was below 20% (% coefficient of variations: %C.V.) Good accuracy was observed for both the intra-day or inter-day assays, as indicated by the minimal deviation of mean values found with measured samples from that of the theoretical values (below +/-15 and +/-20% at high and low concentration range, respectively. The limit of quantification was accepted as 0.1 nmol using 100-microl samples. The mean recovery for DFMO and the internal standard were greater than 95%. The method was free from interference from commonly used drugs including antimalarials and antihelminthics. The method appears to be robust and has been applied to a pharmacokinetic study of DFMO in patients with African trypanosomiasis following oral doses of Ornidyl (Aventis Pharma, Frankfurt, Germany) at 500 mg/kg body weight (125 mg q.i.d.) for 14 days.

Calibration↗

Determination of three phthalate metabolites in human urine using on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry.

An on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (on-line SPE-HPLC-MS/MS) method was developed for the analysis of metabolites of three phthalate esters in human urine at the low nanogram per milliliter level. The recoveries were above 84.3% and relative standard deviations varied from 0.8 to 4.8%. The compounds along with their deuterated internal standards were detected in the negative ion mode by selective reaction monitoring and the accuracy of the method was improved by isotope dilution. Monobutyl phthalate was detected with median level of 22.5 ng/ml. The median levels for monobenzyl phthalate and monoethylhexyl phthalate were less than the limit of quantitation (LOQ). The on-line SPE-HPLC-MS/MS method allowed the possibility of determining these metabolites within a short time, with increased sensitivity and by using decreased amounts of sample and solvent.

Calibration↗