Nondestructive quality control for microarray production.

Abstract

The use of microarrays to monitor gene expression has become a standard research tool at both academic and industrial research institutions. Quality control of common printing defects during DNA deposition onto glass substrates is critical to maintaining data integrity and preventing the needless consumption of precious RNA, labeling reagents, and time. Here we demonstrate a nondestructive method for monitoring the quality of every spot on every chip of a microarray production run. We have identified many common manufacturing defects, while not perturbing the attachment of our oligonucleotide target to the substrate or altering further hybridization. This protocol is simple, fast, and inexpensive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeffrey R Shearstone, Norman E Allaire, Michael E Getman, Steven Perrin. 2002. Nondestructive quality control for microarray production.. https://doi.org/10.2144/02325st06

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimizing spotting solutions for increased reproducibility of cDNA microarrays.

The ability to extract meaningful information from transcriptome technologies such as cDNA microarrays relies on the precision, sensitivity and reproducibility of the measured values for a given gene across multiple samples. Given the lack of a 'gold standard' for the production of microarrays using current technologies, there is a high degree of variation in the quality of data derived from microarray experiments. Poor reproducibility not only adds to the cost of a given study but also leads to data sets that are difficult to interpret. For glass slide DNA microarrays, much of this variation is introduced systematically, during the spotting, or deposition, of the DNA onto the slide surface. In order to reduce this type of systematic variation we tested spotting solutions containing different detergent additives in the presence of one of two different denaturants and determined their effect on spot quality. We show that spotting cDNA in a solution consisting of the zwitterionic detergent 3-[(3-cholamidopropyl)dimethylammonio]-1-propane sulfonate (CHAPS) in the presence of formamide or dimethyl sulfoxide yields spots of superior quality in terms of morphology, size homogeneity and signal reproducibility, as well as overall intensity, when used with popular, commercially available slides.

Carbocyanines↗

The use of fluorescence resonance energy transfer to monitor dynamic changes of lipid-DNA interactions during lipoplex formation.

Fluorescence resonance energy transfer (FRET) was used to monitor interactions between Cy3-labeled plasmid DNA and NBD-labeled cationic liposomes. FRET data show that binding of cationic liposomes to DNA occurs immediately upon mixing (within 1 min), but FRET efficiencies do not stabilize for 1-5 h. The time allowed for complex formation has effects on in vitro luciferase transfection efficiencies of DOPE-based lipoplexes; i.e., lipoplexes prepared with a 1-h incubation have much higher transfection efficiencies than samples with 1-min or 5-h incubations. The molar charge ratio of DOTAP to negatively charged phosphates in the DNA (DOTAP+/DNA-) also affected the interaction between liposomes and plasmid DNA, and interactions stabilized more rapidly at higher charge ratios. Lipoplexes formulated with DOPE were more resistant to high ionic strength than complexes formulated with cholesterol. Taken together, our data demonstrate that lipid-DNA interactions and in vitro transfection efficiencies are strongly affected by the time allowed for complex formation. This effect is especially evident in DOPE-based lipoplexes, and suggests that the time allowed for lipoplex formation is a parameter that should be carefully controlled in future studies.

Carbocyanines↗

Intramolecular dimers: a new design strategy for fluorescence-quenched probes.

Fluorogenic probes dual-labeled with reporter and quencher dyes use a change in fluorescence to monitor biochemical events (e.g., substrate binding or enzyme digestion). Such events change the reporter-quencher distance, which affects fluorescence. Recently, it is has been shown that static quenching through intramolecular dimers is an important mechanism that can sometimes be more efficient than Förster resonance energy transfer (FRET).

Carbocyanines↗