PubMed Health⌕ Search

PubMed · 12020074

Processing in the probed-sinewave paradigm is likely retinal.

Abstract

In the probed-sinewave paradigm-used to study the dynamics of light adaptation-a small probe of light is superimposed on a sinusoidally flickering background. Detection threshold for the probe is measured at various times with respect to the flickering background. Here we present such stimuli using three methods: monoptic (the probe and the flickering background are presented to the same eye), dichoptic (the probe is presented to one eye and the flickering background is presented to the other eye), and binocular (the probe and the flickering background are both presented to both eyes). The results suggest that the processing associated with detecting the probe is primarily in the retina (or any place with monocular input). However, the results also suggest a slight amount of processing in the cortex (or any place with binocular input), particularly at the higher frequency of flickering background used here (9.4 Hz vs. 1.2 Hz). A simple schematic model with three ocular-dominance channels is consistent with the results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S S Wolfson, N Graham. Processing in the probed-sinewave paradigm is likely retinal.. https://pubmed.ncbi.nlm.nih.gov/12020074/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Phototransduction in mouse rods and cones.

Phototransduction is the process by which light triggers an electrical signal in a photoreceptor cell. Image-forming vision in vertebrates is mediated by two types of photoreceptors: the rods and the cones. In this review, we provide a summary of the success in which the mouse has served as a vertebrate model for studying rod phototransduction, with respect to both the activation and termination steps. Cones are still not as well-understood as rods partly because it is difficult to work with mouse cones due to their scarcity and fragility. The situation may change, however.

Adaptation, Ocular↗

Oculomotor plasticity: are mechanisms of adaptation for reactive and voluntary saccades separate?

Saccadic eye movements are permanently controlled and their accuracy maintained by adaptive mechanisms that compensate for physiological or pathological perturbations. In contrast to the adaptation of reactive saccades (RS) which are automatically triggered by the sudden appearance of a single target, little is known about the adaptation of voluntary saccades which allow us to intentionally scan our environment in nearly all our daily activities. In this study, we addressed this issue in human subjects by determining the properties of adaptation of scanning voluntary saccades (SVS) and comparing these features to those of RS. We also tested the reciprocal transfers of adaptation between the two saccade types. Our results revealed that SVS and RS adaptations disclosed similar adaptation fields, time course and recovery levels, with only a slightly lower after-effect for SVS. Moreover, RS and SVS main sequences both remained unaffected after adaptation. Finally and quite unexpectedly, the pattern of adaptation transfers was asymmetrical, with a much stronger transfer from SVS to RS (79%) than in the reverse direction (22%). These data demonstrate that adaptations of RS and SVS share several behavioural properties but at the same time rely on partially distinct processes. Based on these findings, it is proposed that adaptations of RS and SVS may involve a neural network including both a common site and two separate sites specifically recruited for each saccade type.

Adaptation, Ocular↗

Remote facilitation in the Fourier domain.

To explore spatial interactions between visual mechanisms in the Fourier domain we measured detection thresholds for vertical and horizontal sine-wave gratings (4.4 deg diameter) over a range of spatial frequencies (0.5-23 c/deg) in the presence of grating and plaid masks with component contrasts of 8%, orientations of +/-45 degrees and a spatial frequency of 1c/deg. The mask suppressed the target grating over a range of +/-1 octave, and the plaid produced more suppression than the grating, consistent with summation of mask components in a broadly tuned contrast gain pool. At greater differences in spatial frequency ( approximately 3 octaves), the plaid and grating masks both produced about 3 dB of facilitation (they reduced detection thresholds by a factor of about square root 2). At yet further distances ( approximately 4 octaves) the masks had no effect. The facilitation cannot be attributed to a reduction of uncertainty by the mask because (a) it occurs for mask components that have very different spatial frequencies and orientations from the test and (b) the large stimulus size and central fixation point mean there was no spatial uncertainty that could be reduced. We suggest the results are due to long-range sensory interactions (in the Fourier domain) between mask and test-channels. The effects could be due to either direct facilitation or disinhibition.

Adaptation, Ocular↗